Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
1995 Chrysler LHSFACTORY OEM SERVICE PROCEDURE
Test 115A - Repairing Scan Tool Blank Screen
NOTE:
For connector terminal identification, see CONNECTOR IDENTIFICATIONΒ
. For wiring diagrams, see appropriate article in ENGINE PERFORMANCE:
- WIRING DIAGRAMS - 3.3L
- WIRING DIAGRAMS - 3.5L
- Perform TEST VER-1 after each repair.CAUTION: Always turn ignition off prior to disconnecting any module connector.
- Turn ignition off. Disconnect scan tool from Data Link Connector (DLC). Using an external voltmeter, check voltage between DLC terminal No. 2 (Pink wire) and chassis ground. If voltage is less than 10 volts, repair Pink wire as necessary. If voltage is more than 10 volts, go to next step.
- Using an external ohmmeter, check resistance between DLC terminal No. 6 (Black/Light Green wire) and chassis ground. If resistance is more than 20 ohms, repair open Black/Light Green wire). If resistance is less than 20 ohms, go to next step.
- Substitute a known-good scan tool cable. If scan tool display is not blank, replace defective scan tool cable. If scan tool display is blank, go to next step.
- Substitute a known-good scan tool cartridge. If scan tool display is not blank, replace defective scan tool cartridge. If scan tool display is blank, replace scan tool.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.