1992 Chrysler ImperialFACTORY OEM SERVICE PROCEDURE

Grounded Field Brushes Test

  1. Locate set of brush holders that are 180 degrees apart and grounded to frame. Connect lead of a self-powered test light to one field brush and touch test light probe against same field brush holder (ground).
  2. Test light should illuminate if continuity exists. Repeat test on other brush 180 degrees opposite. Test light should illuminate if continuity exists. If continuity does not exist, replace complete brush holder plate assembly or complete starter.
  3. Repeat procedure on remaining 2 brushes and holders. On these insulated brush holders, test light should NOT illuminate. If test light does illuminate on insulated brush holders, brush holders and plate are grounded. Replace complete brush holder plate assembly or complete starter.
Chapter Navigation
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.