1992 Chrysler ImperialFACTORY OEM SERVICE PROCEDURE

LH Body

  1. If problem is with trunk release or warning light, go to TEST 36E of the appropriate TESTS W/CODES - BODY CONTROL COMPUTER article in the ENGINE PERFORMANCE section. See following list. If problem is not with trunk release or warning light, ensure DRB-II door lock test is still active. Disconnect Remote Keyless Entry (RKE) module Black connector. Module is located on top, right side of dashboard.
  2. With DRB-II in voltmeter mode, check voltage on RKE Black connector door unlock relay feed circuit (Pink/Violet wire). If voltage fluctuates from zero volts to less than 10 volts, repair open circuit in Pink/Violet wire. Perform VERIFICATION PROCEDURE VER-1Β  .
  3. If voltage fluctuates from zero volts to more than 10 volts, use DRB-II to stop door lock test. With DRB-II in ohmmeter mode, check resistance on RKE Black connector ground circuit (Black wire). If resistance is less than 5 ohms, replace RKE module. Perform VERIFICATION PROCEDURE VER-1Β  . If resistance is more than 5 ohms, repair open circuit in Black wire. Perform VERIFICATION PROCEDURE VER-1Β  .
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.