1990 Chrysler ImperialFACTORY OEM SERVICE PROCEDURE

Rectifier Assembly Test

  1. Check rectifier assembly for poor solder joints, cracks, or signs of overheating. Clean small area of coating from each diode location to assure good electrical contact during testing.
  2. Using an ohmmeter, connect positive test probe to negative diode and negative probe to stator terminal. Ohmmeter should read 7-11 ohms resistance. Move positive test probe to positive diode, no continuity should be detected. See Fig 1. Perform same test procedure on each stator terminal to diode set.
    NOTE: 75HS alternator has 3 sets of diodes. 90HS and 120HS alternators have 4 sets of diodes.
  3. Connect negative ohmmeter probe to positive diode and positive probe to stator terminal. Ohmmeter should read 7-11 ohms resistance. Move negative test probe to negative diode, no continuity should be detected. Perform same test procedure on each stator terminal to diode set. If rectifier does not test as specified, replace rectifier assembly.
Fig 1: Testing Diodes (Nippondenso)
G90E08183Courtesy of CHRYSLER MOTORS.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.