2008 Chevrolet Optra5 LS, AutomaticFACTORY OEM SERVICE PROCEDURE

Circuit/System Testing

    IMPORTANT: If the CKP sensor lead is damaged in any way, replace the CKP sensor.
  1. Ignition OFF, disconnect the harness connector at the crankshaft position (CKP) sensor.
  2. Ignition ON, test for 1.5-2.0 volts between the signal circuit terminal 2 and the low reference circuit terminal 1.
    • If less than the specified range, test the applicable circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM.
    • If greater than the specified range, test the applicable circuit for a short to voltage. If the circuit tests normal, replace the ECM.
  3. If all circuits test normal, test or replace the CKP sensor.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.