2006 Chevrolet Optra5 LS, AutomaticFACTORY OEM SERVICE PROCEDURE

Circuit/System Testing

  1. Ignition OFF, disconnect the harness connector of the heated oxygen sensor (HO2S) 2.
  2. Ignition ON, verify that the HO2S 2 parameter is between 350-500 mV.
    • If less than 350 mV, test the signal circuit of the HO2S for a short to ground. If the circuit/connections test normal, replace the engine control module (ECM).
    • If greater than 500 mV, test the signal circuit of the HO2S for a short to voltage. If the circuit/connections test normal, replace the engine control module (ECM).
  3. IMPORTANT: The test lamp is used to load the circuit and may not illuminate.
  4. Connect a test lamp between the low reference circuit of the HO2S and B+.
  5. Ignition ON, test for less than 0.1 volt between the low reference circuit of the HO2S and ground.
    • If greater than 0.1 volt, test the low reference circuit of the HO2S for a short to voltage or an open/high resistance. If the circuit/connections test normal, replace the ECM.
  6. Install a 3-amp fused jumper wire between the signal circuit and the low reference circuit of the HO2S and verify the appropriate HO2S parameter is less than 60 mV.
    • If greater than 60 mV, test the signal circuit of the HO2S for an open/high resistance. If the circuit/connections test normal, replace the ECM.
  7. Verify that none of the following conditions exist:
    • Lean or rich fuel injectors-Refer to Fuel Injector Balance Test with Special ToolΒ .
    • Water intrusion in the HO2S harness connector.
    • Low or high fuel system pressure-Refer to Fuel System DiagnosisΒ .
    • Fuel that is contaminated
    • Fuel saturation of the evaporative emission (EVAP) canister.
    • Exhaust leaks near the HO2S.
    • Engine vacuum leaks.
    • If you find any of the above conditions, repair as necessary.
  8. If all circuits/connections test normal, replace the HO2S.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.