Circuit/System Testing

  1. Ignition ON, attempt to establish communication with the TCM with a scan tool.
  2. Ignition OFF, disconnect the harness connector of the TCM.
  3. Ignition ON, verify that 1.5-3.4 volts is available between the CAN serial data low and the CAN serial data high circuits.
    • If the voltage is not within the specified range, test the CAN communication circuits between the ECM and the TCM for an open, short to ground, or a short to voltage.
    • If the circuits/connections test OK, replace the ECM.
  4. If the circuits/connections test OK, replace the TCM.