Installation Procedure
- Install the generator to the vehicle.
- Install the generator upper bracket to the vehicle. Secure the generator bracket with the bolts.
Tighten:Β Tighten the generator upper bracket bolts to 45 N.m (32 lb ft).
- Install the adjusting bolt (1) and pivot bolt (2) to the generator.
- Install the drive belt to the pulleys.
- Remove slack from the belt by pulling on the generator in order to obtain 9-11 mm (0.35- 0.43 in) of belt deflection under 10 kg (22 lbs) of force.
- Secure the generator with the adjusting bolt and pivot bolt.
Tighten:Β Tighten the generator bolts to 23 N.m (17 lb ft).
- Connect the electrical connector to the generator B+ terminal. Secure the connector with one nut and the rubber protector.
Tighten:Β Tighten the electrical connector nut to 8 N.m (71 lb in).
- Connect the generator electrical connector.
- Install the air cleaner hose.
- Connect the negative battery cable.
Tighten:Β Tighten the negative battery cable-to-negative battery terminal retainer to 8 N.m (71 lb in).
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.