2004 Chevrolet Impala LSFACTORY OEM SERVICE PROCEDURE

Installation Procedure

NOTE: Refer to Fastener Notice in Cautions and Notices.
  1. Install the PCM to the PCM electrical connectors.

    Tighten:Β  Tighten the connectors to 8 N.m (71 lb in).

  2. Install the PCM and the wiring harness to the air cleaner housing assembly (3).
  3. Install the air cleaner housing cover (1).
  4. Install the air cleaner housing cover screws (2).

    Tighten:Β  Tighten the screws to 4 N.m (35 lb in).

  5. Fig 1: View Of Air Cleaner Housing, Bolts, PCM & Harness
    GM444496Courtesy of GENERAL MOTORS CORP.
  6. Install the air cleaner intake duct. Refer to Air Cleaner Intake Duct ReplacementΒ .
  7. Install the left front inner fender brace. Refer to Brace Replacement - Front Fender Upper Diagonal in Body Front End.
  8. Connect the negative battery cable. Refer to Battery Negative Cable Disconnect/Connect Procedure in Engine Electrical.
  9. The new PCM must be programmed. Refer to Service Programming System (SPS) in Programming.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.

Rather have a pro handle this?

A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.

Comes to youSame-day available12-month warranty
Get a Free Quote

No obligation. See pricing before you book.