2002 Chevrolet Venture PlusFACTORY OEM SERVICE PROCEDURE

Battery, Charging System And Starting System: Specifications

Fastener Tightening Specifications

Application Specification
Metric English
Battery Hold Down Bolt 18 N.m 13 lb ft
Battery Negative Terminal Bolt 15 N.m 11 lb ft
Battery Negative Cable Bolt to Frame Rail 8 N.m 71 lb in
Battery (Positive) Cable Junction Block Lead Nut 15 N.m 11 lb ft
Battery Positive Terminal Bolt 15 N.m 11 lb ft
Battery Tray Bolts 5 N.m 44 lb in
Generator Pulley Shaft Nut 100 N.m 74 lb ft
Starter Bolt(s) 43 N.m 32 lb ft
Starter Solenoid BAT Terminal Nut 9.5 N.m 89 lb in
Starter Solenoid S Terminal Nut 2.3 N.m 20.5 lb in
Underhood Accessory Wiring Juntion Block Nuts 2 N.m 18 lb in
Transaxle Stud Nut 25 N.m 18 lb ft
Generator Bolt (Long) 50 N.m 37 lb ft
Generator Bolt (Short) 50 N.m 37 lb ft
Generator Output BAT Terminal Nut 20 N.m 15 lb ft
Generator Pivot Bolt 50 N.m 37 lb ft
Generator Rear Brace Nut 25 N.m 18 lb ft
Fig 1: Battery Usage
G01829706Courtesy of GENERAL MOTORS CORP.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.