2002 Chevrolet Astro Van Cargo, AWDFACTORY OEM SERVICE PROCEDURE
Test E: Scan Tool Does Not Power Up: Testing
WARNING: This page is about a different car, the 2001 GMC Safari and 2001 Chevrolet Astro. However, it is still accessible from the selected car via links, so may be relevant.
- Check for battery voltage at DLC terminal No. 16 (Orange wire). If battery voltage exists, go to next step. If battery voltage does not exist, repair open, blown AUX POWER (25-amp) fuse or short to ground as necessary. After repair, go to DIAGNOSTIC SYSTEM CHECK INDEX table under SELF-DIAGNOSTIC SYSTEM.
- Check for open circuit between DLC terminal No. 4 (Black/White wire) and ground. If no problem is found, go to next step. If problem is found, repair open or high resistance between DLC and ground. After repair, go to DIAGNOSTIC SYSTEM CHECK INDEX table under SELF-DIAGNOSTIC SYSTEM.
- Check for damage and poor connections on DLC terminals No. 4 and No. 16. If no problem is found, go to next step. If problem is found, repair as necessary. After repair, go to DIAGNOSTIC SYSTEM CHECK INDEX table under SELF-DIAGNOSTIC SYSTEM.
- Check scan tool. Follow scan tool manufacturer's instructions. After repair, go to DIAGNOSTIC SYSTEM CHECK INDEX table under SELF-DIAGNOSTIC SYSTEM.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.