2000 Chevrolet Tracker 4D Utility, RWD, AutomaticFACTORY OEM SERVICE PROCEDURE

Generator Specifications

GENERATOR SPECIFICATIONS

Application Specification
Brush Length
Limit (Minimum) .08" (2 mm)
Standard .63" (16 mm)
Capacitor 0.5 Microfarads
Generated Regulator Output 13.2-15.0 Volts
Rotor Resistance
Between Rotor & Slip Rings More Than 5 Ohms
Between Slip Rings 2.5-2.9 Ohms
Stator Resistance
Between Stator Core & Stator Leads More Than 5 Ohms
Between Stator Leads Less Than 5 Ohms
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.