1987 Chevrolet Sprint TurboFACTORY OEM SERVICE PROCEDURE

Oxygen Sensor

  1. Warm engine to normal operating temperature. Disconnect oxygen sensor connector.
  2. Connect voltmeter between oxygen sensor side terminal (of disconnected connector) and ground. See Fig 1 . DO NOT apply voltage to oxygen sensor.
    Fig 1: Connecting Voltmeter to Oxygen Sensor
    G42236Courtesy of GENERAL MOTORS CORP.
  3. With engine at 1500-2000 RPM, turn WOT microswitch on by moving microswitch lever. See Fig 2 . Check that voltmeter reads about .8 volts.
    Fig 2: Moving WOT Microswitch Lever
    G61349Courtesy of GENERAL MOTORS CORP.
  4. With engine at 1000-1500 RPM, disconnect vacuum hose at intake manifold. Check that voltmeter reads near zero. Reconnect vacuum hose and oxygen sensor connector.