1987 Chevrolet Sprint TurboFACTORY OEM SERVICE PROCEDURE

Mixture Control Solenoid Valve

  1. Remove duty check connector cap and short the terminals with a lead wire. See Fig 1 . Turn ignition on and off repeatedly without starting engine.
  2. Using finger, touch carburetor body near Mixture Control Solenoid (MCS) valve and make sure carburetor makes small vibrations according to ignition switch operation.
  3. Vibrations from MCS indicate proper operation. If there are no vibrations, replace MCS in carburetor.
Fig 1: Shorting Duty Check Connector Terminals
G61348Courtesy of GENERAL MOTORS CORP.