Electronic Ignition System Diagnosis

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle (Diagnostic System Check - Vehicle) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (Strategy Based Diagnosis) for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions (Diagnostic Procedure Instructions) provides an overview of each diagnostic category.

Circuit/System Description

The ignition system uses individual ignition coil/module assemblies for each cylinder. The engine control module (ECM) controls the individual coils by transmitting timing pulses on the ignition control (IC) circuit of each ignition coil/module to enable a spark event. Each ignition coil/module has the following circuits:

* An ignition voltage circuit
* A ground circuit
* An IC control circuit
* A low reference circuit

Reference Information
Schematic Reference

Engine Controls Schematics ([1][2]Electrical Diagrams)
Connector End View Reference

Component Connector End Views (Connector Views)
Electrical Information Reference

* Circuit Testing ()
* Connector Repairs ()
* Testing for Intermittent Conditions and Poor Connections ()
* Wiring Repairs ()

Scan Tool Reference

Control Module References (Programming and Relearning) for scan tool information
Special Tools

J 26792 HEI Spark Tester

Circuit/System Verification

Observe the Engine Controls Schematic for the ignition coils/modules, and review the Ignition System Specifications to verify the following:

* The ignition coil/modules are correctly connected
* The proper firing order
* The proper spark plug type
* The proper spark plug gap and torque
Refer to Ignition System Specifications (Specifications).

Circuit/System Testing

Important: Verify that the engine is in good mechanical condition before continuing with this diagnostic.


1. Turn OFF the ignition.
2. Inspect the fuse that supplies voltage to the ignition coil/modules.

• If the fuse is open, then test the spliced circuits and the individual ignition coil/modules for a short to ground.

3. Disconnect the affected ignition coil/module.
4. Connect a test lamp between the ignition coil/module ignition 1 voltage circuit terminal A and a good ground.
5. Turn ON the ignition.
6. With the test lamp still connected, measure for battery voltage between the ignition 1 voltage circuit and a good ground.

• If the voltage is not within 1 volt of battery voltage, repair the high resistance or the open in the ignition 1 voltage circuit.

7. Turn OFF the ignition, and all electrical accessories. Allow sufficient time for all of the control modules to power down before taking a resistance measurement.
8. Measure for a proper value of less than 5 ohms between the ground circuit terminal D of the affected ignition coil/module and a good ground.

• If the resistance is more than 5 ohms, repair the high resistance or the open in the ground circuit.

9. Exchange the affected ignition coil/module with the ignition coil/module of a good cylinder.
10. Start the engine and observe the scan tool.

• If the misfire transfers with the suspect ignition coil/module, replace as needed.
• If the misfire does not transfer with the suspect ignition coil/module, observe the component testing procedures below, and replace the spark plug if needed.

Component Testing

* Use the Spark Plug Inspection procedure to verify the integrity of the spark plugs. Refer to Spark Plug Inspection (Testing and Inspection).
* Use the J 26792 to verify the output of each ignition coil/module.

Repair Instructions

Perform the Diagnostic Repair Verification (Verification Tests) after completing the diagnostic procedure.

* Ignition Coil Replacement - Bank 1 (Ignition Coil Replacement - Bank 1)
* Ignition Coil Replacement - Bank 2 (Ignition Coil Replacement - Bank 2)
* Spark Plug Replacement (Service and Repair)

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.