2000 Cadillac Seville SLSFACTORY OEM SERVICE PROCEDURE

Generator Functional Test

  1. Start engine and observe charge indicator light on Instrument Panel Cluster (IPC) or message in Driver Information Center (DIC). If charge indicator light illuminates or DIC displays a charging system message, go to next step. If charge indicator light does not illuminate or DIC does not display a charging system message, problem is probably intermittent.
  2. NOTE: Green POWER lamp of tester should remain illuminated while tester is being used.
  3. Turn ignition off. Using CS Electronic Generator Tester (J41450-B), connect Red lead to generator output terminal and Black lead to metal generator housing. If Green POWER lamp is not on, go to next step. If Green power lamp is on, go to step  4 .
  4. Using a DVOM, measure voltage between output terminal of generator and battery negative terminal. If battery voltage exists, go to step  10 . If battery voltage does not exist, go to step  9 .
  5. CAUTION: Make sure load is completely turned off before connecting or disconnecting carbon pile load tester to battery.
  6. Connect carbon pile tester to battery. Connect inductive ammeter to output circuit of generator. Disconnect generator harness connector. Locate matching harness connector on CS Electronic Generator Tester (J41450-B) and connect it to generator. If Red DIAGNOSTIC lamp is on, go to next step. If Red DIAGNOSTIC lamp is off, go to step  11 .
  7. Start engine and allow to idle for 30 seconds. Increase engine speed to 2500 RPM. If Red DIAGNOSTIC lamp is off, go to next step. If Red DIAGNOSTIC lamp is on, go to step  11 .
  8. Maintain engine speed at 2500 RPM. Turn on load of carbon pile tester and increase load until load is equal to test value of generator (105 amps). If Red DIAGNOSTIC lamp is not on, go to next step. If Red DIAGNOSTIC lamp is on, go to step  11 .
  9. Maintain engine speed at 2500 RPM and continue to operate generator at load test value. Using a DVOM, measure voltage drop between generator output terminal and positive battery terminal. If voltage drop is less than 0.5 volt, go to next step. If voltage drop is more than 0.5 volt, go to step  9 .
  10. Maintain engine speed at 2500 RPM and continue to operate generator at load test value. Using a DVOM, measure voltage drop between generator metal housing and negative battery terminal. If voltage drop is less than 0.5 volt, go to step  12 . If voltage drop is more than 0.5 volt, go to step  10 .
  11. Repair high resistance or open in Red and Black wires between generator output terminal and positive battery terminal. See WIRING DIAGRAMS  . Go to step  12 .
  12. Repair high resistance or open in ground circuit of generator. See WIRING DIAGRAMS  . Go to step  12 .
  13. Check generator connector for poor connections. If connector is good, replace generator. See GENERATOR  under REMOVAL & INSTALLATION. Go to next step.
  14. Retest system to verify repair.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.

Rather have a pro handle this?

A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.

Comes to youSame-day available12-month warranty
Get a Free Quote

No obligation. See pricing before you book.