1997 Cadillac Seville SLSFACTORY OEM SERVICE PROCEDURE

Memory Function Switch Inoperative

  1. If diagnostic system check was performed, go to next step. If diagnostic system check was not performed, go to DIAGNOSTIC SYSTEM CHECKΒ  .
  2. Using test light, backprobe between MMM connector terminal E1 (Orange wire) and memory function switch connector terminal "E" (Black wire). If test light illuminates, go to next step. If test light does not illuminate, go to step 6).
  3. Using test light, backprobe between MMM connector terminal E1 (Orange wire) and appropriate memory function connector switch terminal. See WIRING DIAGRAMSΒ  . Operate suspect memory switch. If test light illuminates, go to next step. If test light does not illuminate, go to step 7).
  4. Using test light, backprobe between MMM connector terminal E1 (Orange wire) and appropriate MMM connector terminal. See WIRING DIAGRAMSΒ  . Operate suspect memory switch. If test light illuminates, go to next step. If test light does not illuminate, go to step 8).
  5. Replace MMM. Perform DIAGNOSTIC SYSTEM CHECKΒ  .
  6. Check for open in Black wire between memory function switch and ground. If circuit is okay, go to next step. If circuit is not okay, go to step 9).
  7. Replace memory function switch. Perform DIAGNOSTIC SYSTEM CHECKΒ  .
  8. Repair problem in appropriate wire. See WIRING DIAGRAMSΒ  . Perform DIAGNOSTIC SYSTEM CHECKΒ  .
  9. Repair open in Black wire between memory function switch and ground. Perform DIAGNOSTIC SYSTEM CHECKΒ  .
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.