1996 Cadillac Seville SLSFACTORY OEM SERVICE PROCEDURE

DTC PZ1972, Low Power Control Fault: Testing

  1. Turn ignition switch to OFF position. Disconnect PZM connector. Using DVOM, measure resistance between PZM connector terminal B11 and ground. If resistance is greater than 5 ohms, replace PZM. If resistance is 5 ohms or less, go to next step.
  2. Remove 10-amp PZM fuse located in trunk compartment fuse block. Using DVOM, measure resistance between PZM connector terminal B11 and ground. If resistance is 5 ohms or less, repair short to ground in low power control output circuit between 10-amp PZM fuse and PZM. If resistance is greater than 5 ohms, go to next step.
  3. Install 10-amp PZM fuse. Remove 20-amp CLUSTER fuse, 10-amp RADIO/PHONE fuse and 30-amp AMP fuse, all located in trunk compartment fuse block. Using DVOM, measure resistance between PZM connector terminal B11 and ground. If resistance is 5 ohms or less, repair short to ground in controlled power relay circuit between 20-amp CLUSTER fuse, 10-amp RADIO/PHONE fuse, 30-amp AMP fuse and controlled power relay. If resistance is greater than 5 ohms, go to next step.
  4. Install 10-amp RADIO/PHONE fuse. Using DVOM, measure resistance between PZM connector terminal B11 and ground. If resistance is 5 ohms or less, repair short to ground in fuse circuit between 10-amp RADIO/PHONE fuse and accessory time delay cut-off relay. If resistance is greater than 5 ohms, go to next step.
  5. Install 20-amp CLUSTER fuse. Using DVOM, measure resistance between PZM connector terminal B11 and ground. If resistance is 5 ohms or less, repair short to ground in fuse circuit between 20-amp CLUSTER fuse and instrument panel cluster. If resistance is greater than 5 ohms, repair short to ground in fuse circuit between 30-amp AMP fuse and audio relay or amplifier.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.