1992 Cadillac Seville BaseFACTORY OEM SERVICE PROCEDURE

Note On Intermittents

Probe fuel pump test point using a voltmeter to ground. Turn ignition on, and observe voltmeter. Voltmeter should indicate battery voltage for 2 seconds and then drop to zero. If voltage reading stays at battery voltage for longer than 2 seconds, check for sticking fuel pump relay contacts. Repeat test several times. Continue probing fuel pump test point to ground. Start engine, and then turn it off. Voltage should drop immediately to zero. If voltage does not immediately drop to zero, check oil pressure switch contacts.

Fig 1: PCM Code E019, Schematic, Shorted Fuel Pump Circuit
G92A05012Courtesy of GENERAL MOTORS CORP.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.