1990 Cadillac Allante F7/ME9FACTORY OEM SERVICE PROCEDURE

ECM DTC EO42: Left O2 Sensor Lean: Description

The ECM provides a 0.45 volt reference signal to the oxygen sensor on CKT 412. When the oxygen sensor is cold (below 200Β°C), the oxygen sensor signal voltage will be around 0.45 volts and the ECM will keep the system is open loop operation. When the oxygen sensor is warm (above 200Β°C), the oxygen sensor will swing from rich to lean rapidly, at least one swing every two seconds, if the ECM is in good control of the air fuel mixture. Code EO42 is designed so that if the oxygen sensor stays at a lean voltage for more than 50 seconds during the test conditions, Code EO42 will set. Code EO42 will set when:

  1. There is an oxygen sensor circuit fault giving a false lean indication.
  2. When the air fuel ratio is actually lean due to a vacuum leak or fuel control system fault.

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.