1988 Cadillac Seville BaseFACTORY OEM SERVICE PROCEDURE

Notes On Intermittent

Code EO32 can be set by an open 5-volt reference signal between ECM and sensor, an open MAP signal between sensor and ECM, or a defective MAP sensor.

Manipulate affected wiring and connectors while observing ECM parameter ED02. Apply and release vacuum to MAP sensor vacuum port using a vacuum source. If ECM parameter ED02 displays less than 17 kPa, condition has been induced and cause of intermittent can be repaired. If wiring and connectors are okay, substitute a known good sensor and retest.

Review snapshot data parameters stored with this code to verify failure. If failure is verified, check and repair intermittent wiring connection or sensor.

Fig 1: Schematic, Code EO32, Open MAP Sensor Circuit
G57295
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.