1988 Cadillac Seville BaseFACTORY OEM SERVICE PROCEDURE

Chart C4 - Est System Check

The HEI distributor produces one 5-volt distributor reference pulse each time a cylinder reaches 10Β° BTDC (base ignition timing). These reference pulses are sent from distributor to ECM on circuit No. 430. ECM adds spark timing information to reference pulses received from HEI and sends out a 5-volt EST pulse over circuit No. 423.

The ECM can choose to control spark timing. The HEI by-pass circuit (circuit No. 424) is turned on by the ECM when the ECM wishes to control timing. The HEI by-pass circuit is turned off and the HEI module grounds EST circuit No. 423.

Circuit No. 453F is a common ground between ECM and HEI. The ECM and HEI compare by-pass, EST, and reference pulses to ground over this circuit. A circuit No. 453 open to the HEI or ECM can cause a failure of the ECM to recognize a reference pulse, or the HEI module to recognize an EST pulse.

The ECM compares status of EST circuit to the status of the by-pass circuit in order to detect a fault code E023. Possible causes for this code are: circuit No. 423 open or grounded. Circuit No. 424 open or grounded. Circuit No. 453F open to ground at HEI or ECM. Poor connections in circuit No. 450. ECM or HEI module faults.

NOTE: Test numbers refer to test numbers on diagnostic chart.
  1. Four 12" jumper wires must be obtained for use in diagnostic procedure. Jumper wires MUST have male and female Weatherpack Connectors (12014836 and 12014837) on either end. With distributor connector unplugged, use jumper wires to reconnect terminals. Use instructions provided in ECM CODE EO23 - EST CIRCUIT PROBLEM chart.
  2. With only distributor reference and distributor reference ground jumpered, engine will run on back-up spark control. This step checks for proper ground connection between ECM and engine, and between ECM and HEI.
  3. This step ensures that ECM is providing an EST output signal over circuit No. 423.
  4. This step checks the ability of the HEI module to ground EST signal with an open by-pass circuit.
Fig 1: Flow Chart C4 Schematic, EST System Check
G57257
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.