1987 Cadillac SevilleFACTORY OEM SERVICE PROCEDURE

Chart A6 - Open Loop Diagnosis (O2 Sensor Not Ready)

The ECM provides a .45 volt reference to oxygen sensor on circuit No. 412. When warm, a properly operating oxygen sensor will drive the .45 volt reference lower (below .45 volts) to indicate lean mixtures and higher (above .45 volts) to indicate a rich mixture.

NOTE: The following step numbers refer to the numbers in the accompanying flow chart(s).
  1. At key on with oxygen sensor disconnected, parameter "ED07" should read .45 volts (nominal). Lower or higher voltage indicates circuit problems.
  2. The ECM compares voltage on circuit No. 412 to ground voltage on circuit No. 413. It is essential that oxygen sensor ground and ECM ground on pin D6 show good continuity with no voltage difference with engine running.
Fig 1: Flow Chart A6 - Open Loop Diagnosis - O2 Sensor Not Ready
G4328
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.