1987 Cadillac SevilleFACTORY OEM SERVICE PROCEDURE

Notes On INTERMITTENTS

If intermittent code "B112" is being set, manipulate related wiring while observing BCM data parameter "BD28". If failure is induced, reading will jump from its normal value to a reading outside range of -29 to 189Β°F (-34 to 87Β°C).

If the value displayed by data parameter "BD28" is not reasonably close to corresponding gauge pressure reading, check for poor terminal contact or replace sensor.

Fig 1: Schematic, Code B112 - A/C Low Side Temp. Sensor Circuit