1987 Cadillac SevilleFACTORY OEM SERVICE PROCEDURE

Notes On INTERMITTENTS

A code "B110" will be stored in memory whenever the ambient temperature drops below -29°F (-34°C). This code should be ignored if this cause is suspected.

If intermittent code "B110" is being set, manipulate related wiring while observing BCM data parameter "BD26". If failure is induced, reading will jump from its normal value to a reading outside range of -29°F (-34°C) to 189°F (87°C).

If value displayed by "BD26" is not reasonably close to actual temperature of air at sensor, check for poor terminal contact or replace sensor. The temperature of air at sensor can be influenced by a hot radiator, if sufficient air is not passing by sensor.

Fig 1: Schematic, Code B110 - Outside Air Temperature Sensor Ckt
G57386