2017 Buick Enclave ConvenienceFACTORY OEM SERVICE PROCEDURE

Front View Camera Module Learn

For North American SPS users, Calibration will NOT start automatically  and will need to be initiated with GDS2. For European SPS users, Calibration will start automatically  and will not need to be initiated with GDS2.

The calibration process for the front view camera system is necessary when a front view camera module is replaced by a new one. This process is required when only replacing the windshield  and the front view camera module has been mounted again properly. This is a self-calibration procedure, which starts after the SPS configuration and setup is done. This process shall be completed within 3 - 10 min when the correct driving conditions are met.

If conditions are not met correct, the front view camera module shall continuously run the service point calibration until successfully completed. This process shall work across ignition cycles and shall not be required to be reinitialized at start up.

When this process is initiated on modules with the lane departure warning feature, the front view camera module shall command the lane departure warning system amber indicator on continuously until the alignment is completed. Once alignment is complete, the amber indicator will clear automatically.

Operate the system in the following conditions until the alignment is complete:

  • Clean windshield.
  • Avoid lane change.
  • Drive during the daytime.
  • Lane departure warning system is ON.
  • Maintain vehicle speeds between 56 - 90 km/h (35 - 56 MPH).
  • Ensure the road contains visible references (well defined lane markings, curbs, guard rails, fences, buildings, etc.).

Calibration Procedure (Required for North American SPS users)

  1. Apply the parking brake.
  2. Place the transmission in Park (if applicable)
  3. Install scan tool
  4. Navigate to the module diagnostics menu
  5. Select Frontview Camera Module
  6. Select Configuration/ Reset Functions menu Item
  7. Select the Frontview Camera Learn procedure and follow the directions displayed on the screen.
  8. Drive the vehicle to complete calibration.

When the calibration is complete, the amber indicator will clear automatically, if well defined lane markings were seen and the vehicle speed was between 56 - 90 km/h (35 - 56 MPH). Then the system is ready to assist.

One or more of the following conditions may increase the length of time required to complete the self-calibration procedure:

  • Heavy traffic
  • Mountained roads
  • Curves in roadway
  • Poor contrast lane markings
  • Botts' Dots type lane markings
  • Operating the vehicle speed is greater than 90 km/h (56 MPH)
  • Driving through snow or fog, driving at night, or driving directly into the sun

Conditions that will prevent completion of the self-calibration procedure:

  • Operating the vehicle with speed less than 56 km/h (31 MPH)
  • No visible lane markings
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.