2013 Buick Regal GS, Automatic TransFACTORY OEM SERVICE PROCEDURE

Circuit/System Testing

NOTE:
  • Terminal and connector identifiers will be different depending on the individual device being tested. Use Schematic Reference and Connector End View Reference to identify device's connector, B+, ground, and serial data circuit terminals.
  • A loss of serial data communications DTC does not represent a failure of the master control module that set it.
  1. Ignition OFF, disconnect the harness connector at the S56 Radio Control Multifunction Switch.
  2. Test for less than 10 Ω between the ground circuit terminal and ground.
    • If 10 Ω or greater 
    1. Ignition OFF.
    2. Test for less than 2 Ω in the ground circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, repair the open/high resistance in the ground connection.
    • If less than 10 Ω 
  3. Ignition ON.
  4. Verify a test lamp illuminates between the B+ circuit terminal and ground.
    • If the test lamp does not illuminate and the circuit fuse is good 
    1. Ignition OFF.
    2. Test for less than 2 Ω in the B+ circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, verify the fuse is not open and there is voltage at the fuse.
    • If the test lamp does not illuminate and the circuit fuse is open 
    1. Ignition OFF.
    2. Test for infinite resistance between the B+ circuit terminal and ground.
      • If less than infinite resistance, repair the short to ground on the circuit.
      • If infinite resistance, replace the S56 Radio Control Multifunction Switch.
    • If the test lamp illuminates 
  5. Ignition ON.
  6. Test for 2-12 V between the serial data circuit terminal and ground.
    • If less than 2 V 
    1. Ignition OFF, disconnect the harness connector at the A22 Radio Controls.
    2. Test for infinite resistance between the serial data circuit terminal and ground.
      • If less than infinite resistance, repair the short to ground on the circuit.
      • If infinite resistance
    3. Test for less than 2 Ω in the serial data circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω
    4. Replace the A22 Radio Controls.
    • If greater than 12 V 
    1. Ignition OFF, disconnect the harness connector at the A22 Radio Controls.
    2. Ignition ON.
    3. Test for less than 1 V between the serial data circuit terminal and ground.
      • If 1 V or greater, repair the short to voltage on the circuit.
      • If less than 1 V
    4. Replace the A22 Radio Controls.
    • If between 2-12 V 
  7. Replace the S56 Radio Control Multifunction Switch.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.