1980 Buick Skyhawk Base, Automatic TransFACTORY OEM SERVICE PROCEDURE

All Others - Functional Test

  1. Inspect check valve whenever working on system. If pump was inoperative and had signs of exhaust gases reaching pump, a failed check valve would be indicated.
  2. Seal off vacuum supply to diverter valve by pinching hose. Hold for at least one second, then release hose. Air should now be exhausting from bottom of diverter valve. It should do so for about four seconds. Replace diverter valve if air does not exhaust.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.