Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
Emergency Programs
There are a total of four emergency operation programs stored in the MS S52 control module. The MS S52 control module will activate one of these programs depending on which fault is present or what the failed component is. With any fault that is relevant to the EDR system, the engine's output torque will be reduced to provide limited driveability of the vehicle.
EMERGENCY PROGRAM #1. - Engine operation with PWG input. The engine's output torque is limited to 480 Nm. This program will set with faults in one PWG sensor input or one throttle valve feedback input.
EMERGENCY PROGRAM #2. - Engine operation through the idle valve actuator. The engine's output torque is limited to 300 Nm and the vehicle's speed to 70 MPH. With program #2, the throttle valves are shut down and only the idle valve is used for engine operation. This program will set with a fault in one air mass sensor input and one PWG sensor input.
EMERGENCY PROGRAM #3. - Engine operation with jammed throttle valves. The engine's output torque is limited to 300 Nm and the speed is limited to 35 MPH. This is carried out through ignition and injection intervention if the MS S52 senses that the throttle valves are jammed or stuck and cannot be closed by applying power through the EDR actuator.
EMERGENCY PROGRAM #4. - Engine operation with a control module internal fault. The engine's output torque is limited to 250 NM and the speed is limited to 35 MPH. Depending on the degree of the fault, the control module with the dual processors will enable limited engine operation.
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.