1993 BMW 740iFACTORY OEM SERVICE PROCEDURE

Bench Testing: Stator

  1. Place ohmmeter on lowest scale. Measure resistance between 2 of the 3 sets of wires. Move one ohmmeter lead to the other set of wires. Check resistance between the remaining set of wires. Resistance values must be identical. If resistance is incorrect, stator has open or shorted windings and must be replaced.
  2. Place ohmmeter on X1000 scale. Connect ohmmeter between stator core and each stator lead. Continuity should not exist. If continuity exists, stator is grounded and must be replaced.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.

Rather have a pro handle this?

A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.

Comes to youSame-day available12-month warranty
Get a Free Quote

No obligation. See pricing before you book.