1983 BMW 633CSi AutomaticFACTORY OEM SERVICE PROCEDURE

Air Temperature Sensor

Turn ignition switch off. Disconnect electrical connector at air flow meter and connect ohmmeter between terminals 6 and 22. Readings should be as follows. If not, replace temperature sensor and air flow meter as an assembly.

TEMPERATURE/RESISTANCE RELATIONSHIP

Temperature Ohms
68Β°F (20Β°C) 2,000-3,000
122Β°F (50Β°C) 760-970