Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2025 Audi Q5 e Premium PlusFACTORY OEM SERVICE PROCEDURE
Gateway Module --, 2025 MY
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Unit | Secondary Parameters | Enable Condition | Unit | Monitor Frequency of Checks | Monitoring Time Length | Unit | MIL Illum. |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LIN | U1050 - Battery Monitoring Control Module No communication | Lost Communication with 12 V Battery Sensor | Message time out | = detected | [-] | Hybrid vehicle AND LV LiIon starter battery AND Ignition AND GW active | = detected = detected = off = true | [-] | continuous | 5000 | [ms] | 2 DCY |
| Hybrid CAN | U014B - Lost Communication With Hybrid/EV Battery Inductive Charging Module | Lost communication with control module for contact-less charging (time out) | Message time out | = detected | [-] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 2.370 | [ms] | 1 DCY |
| U0112 - Lost Communication With Battery Energy Control Module "B" | Lost communication with Battery Energy Control Module "B" (time out) | Message time out | = detected | [-] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 870 | [ms] | 1 DCY | |
| Lost communication with Battery Energy Control Module "B" (time out) | Message time out | = detected | [-] | Driving mode | = active | [-] | continuous | 5.370 | [ms] | 1 DCY | ||
| Lost communication with Battery Energy Control Module "B" (time out) | Message time out | = detected | [-] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 5.370 | [ms] | 1 DCY | ||
| Lost communication with Battery Energy Control Module "B" (time out) | Message time out | = detected | [-] | Driving mode | = active | [-] | continuous | 5.370 | [ms] | 1 DCY | ||
| Lost communication with Battery Energy Control Module "B" (time out) | Message time out | = detected | [-] | Driving mode | = active | [-] | continuous | 5.370 | [ms] | 1 DCY | ||
| Lost communication with Battery Energy Control Module "B" (time out) | Message time out | = detected | [-] | Driving mode | = active | [-] | continuous | 5.370 | [ms] | 1 DCY | ||
| U0298 - Lost Communication With DC/DC Converter Control Module "A" | Lost communication with DC/DC Converter Control Module "A" (time out) | Message time out | = detected | [-] | [(Ignition OR Autonomous HV request) Driving mode] OR Driving mode | = on = commanded on = not active = active | [-] [-] | continuous continuous | 1.645 5.370 | [ms] [ms] | 1 DCY 1 DCY | |
| Lost communication with DC/DC Converter Control Module "A" (time out) | Message time out | = detected | [-] | [(Ignition OR Autonomous HV request) Driving mode] OR Driving mode | = on = commanded on = not active = active | [-] [-] | continuous continuous | 1.645 5.370 | [ms] [ms] | 1 DCY 1 DCY | ||
| U019B - Lost Communication With Battery Charger Control Module "A" | Lost communication with Battery Charger Control Module "A" (time out) | Message time out | = detected | [-] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 1.420 | [ms] | 1 DCY | |
| U0116 - Lost Communication With Coolant Temperature Control Module | Lost communication with Coolant Temperature Control Module (time out) | Message time out | = detected | [-] | Driving mode | = active | [-] | continuous | 5.370 | [ms] | 2 DCY | |
| Lost communication with Coolant Temperature Control Module (time out) | Message time out | = detected | [-] | Driving mode | = active | [-] | continuous | 370 | [ms] | 2 DCY | ||
| U044C - Invalid Data Received From Hybrid/EV Battery Inductive Charging Module | Invalid data received from control module for contact-less charging | Invalid checksum OR Message counter | ≥ 2 consecutive ≥ 8 repetitions | [-] [-] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous continuous | 770 1.970 | [ms] [ms] | 1 DCY | |
| U0413 - Invalid Data Received From Battery Energy Control Module "B" | Invalid data received from Battery Energy Control Module "B" | Invalid checksum OR Message counter | ≥ 2 consecutive ≥ 31 repetitions | [-] [-] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous continuous | 390 680 | [ms] [ms] | 1 DCY | |
| Invalid data received from Battery Energy Control Module "B" | Invalid checksum OR Message counter | ≥ 2 consecutive ≥ 5 repetitions | [-] [-] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous continuous | 1.370 2.870 | [ms] [ms] | 1 DCY | ||
| U0599 - Invalid Data Received From DC/DC Converter Control Module "A" | Invalid data received from DC/DC Converter Control Module "A" | Invalid checksum OR Message counter | ≥ 2 consecutive ≥ 25 repetitions | [-] [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous continuous | 470 1.620 | [ms] [ms] | 1 DCY | |
| Invalid data received from DC/DC Converter Control Module "A" | Invalid checksum OR Message counter | ≥ 2 consecutive ≥ 25 repetitions | [-] [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous continuous | 470 1.620 | [ms] [ms] | 1 DCY | ||
| U049C - Invalid Data Received From Battery Charger Control Module "A" | Invalid data received from Battery Charger Control Module "A" | Invalid checksum OR Message counter | ≥ 2 consecutive ≥ 10 repetitions | [-] [-] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous continuous | 570 1.370 | [ms] [ms] | 1 DCY | |
| FlexRay | U0110 - Lost Communication With Drive Motor Control Module "A" | Lost communication with Drive Motor Control Module "A" (time out) | Message time out | = detected | [-] | [(Ignition OR Autonomous HV request) Driving mode] OR Driving mode | = on = commanded on = not active = active | [-] [-] | continuous continuous | 1.645 5.370 | [ms] [ms] | 1 DCY 1 DCY |
| Lost communication with Drive Motor Control Module "A" (time out) | Message time out | = detected | [-] | [(Ignition OR Autonomous HV request) Driving mode] OR Driving mode | = on = commanded on = not active = active | [-] [-] | continuous continuous | 1.645 5.370 | [ms] [ms] | 1 DCY 1 DCY | ||
| Lost communication with Drive Motor Control Module "A" (time out) | Message time out | = detected | [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous | 5.370 | [ms] | 1 DCY | ||
| U0292 - Lost Communication With Drive Motor Control Module "B" | Lost communication with Drive Motor Control Module "B" (time out) | Message time out | = detected | [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous | 5.370 | [ms] | 1 DCY | |
| Lost communication with Drive Motor Control Module "B" (time out) | Message time out | = detected | [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous | 5.370 | [ms] | 1 DCY | ||
| U0100 - Lost Communication With ECM/PCM "A" | Lost communication with ECM/PCM "A" (time out) | Message time out | = detected | [-] | Driving mode | = active | [-] | continuous | 5.370 | [ms] | 2 DCY | |
| U0411 - Invalid Data Received From Drive Motor Control Module "A" | Invalid data received from Drive Motor Control Module "A" | Invalid checksum OR Message counter | ≥ 2 consecutive ≥ 25 repetitions | [-] [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous continuous | 470 1.620 | [ms] [ms] | 1 DCY | |
| Invalid data received from Drive Motor Control Module "A" | Invalid checksum OR Message counter | ≥ 2 consecutive ≥ 25 repetitions | [-] [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous continuous | 470 1.620 | [ms] [ms] | 1 DCY | ||
| Invalid data signal received from Drive Motor Control Module "A" | Invalid checksum OR Message counter | ≥ 2 consecutive ≥ 5 repetitions | [-] [-] | (Ignition OR Autonomous HV request) AND Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous continuous | 1.370 2.870 | [ms] [ms] | 1 DCY | ||
| U0593 - Invalid Data Received From Drive Motor Control Module "B" | Invalid data received from Drive Motor Control Module "B" | Invalid checksum OR Message counter | ≥ 2 consecutive ≥ 5 repetitions | [-] [-] | (Ignition OR Autonomous HV request) AND Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous continuous | 1.370 2.870 | [ms] [ms] | 1 DCY | |
| Invalid data received from Drive Motor Control Module "B" | Invalid checksum OR Message counter | ≥ 2 consecutive ≥ 5 repetitions | [-] [-] | (Ignition OR Autonomous HV request) AND Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous continuous | 1.370 2.870 | [ms] [ms] | 1 DCY | ||
| System Error | U044C - Invalid Data Received From Hybrid/EV Battery Inductive Charging Module | Implausible signal received from control module for contact-less charging | Wireless HV charging module error state signal | = init | [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous | 5.370 | [ms] | 1 DCY |
| U0413 - Invalid Data Received From Battery Energy Control Module "B" | Implausible signal received from Battery Energy Control Module "B" | HV battery error state signal | = init | [-] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 5.370 | [ms] | 1 DCY | |
| Implausible signal received from Battery Energy Control Module "B" | HV battery current state signal | = init | [-] | Ignition OR | = on | [-] | continuous | 5.370 | [ms] | 1 DCY | ||
| Autonomous HV request | = commanded on | [-] | ||||||||||
| Implausible signal received from Battery Energy Control Module "B" | HV battery voltage signal | = init | [V] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 5.370 | [ms] | 1 DCY | ||
| U0411 - Invalid Data Received From Drive Motor Control Module "A" | Implausible signal received from Drive Motor Control Module "A" | HV voltage converter HV side voltage signal | = init | [V] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 5.370 | [ms] | 1 DCY | |
| U0599 - Invalid Data Received From DC/DC Converter Control Module "A" | Implausible signal received from DC/DC Converter Control Module "A" | DC/DC converter voltage state signal | = init | [-] [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous continuous | 470 1.620 | [ms] [ms] | 1 DCY | |
| U0411 - Invalid Data Received From Drive Motor Control Module "A" | Implausible signal received from Drive Motor Control Module "A" | Power electronics error state signal | = init | [-] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 5.370 | [ms] | 1 DCY | |
| Implausible signal received from Drive Motor Control Module "A" | Power electronics voltage signal | = init | [V] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 5.370 | [ms] | 1 DCY | ||
| U049C - Invalid Data Received From Battery Charger Control Module "A" | Implausible signal received from Battery Charger Control Module "A" | HV charger current state signal | = init | [-] | (Ignition OR Autonomous HV request) HV charging mode Driving mode | = on = commanded on = active = not active | [-] [-] [-] [-] | continuous | 5.370 | [ms] | 1 DCY | |
| Implausible signal received from Battery Charger Control Module "A" | HV charger error state signal | = init | [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous | 5.370 | [ms] | 1 DCY | ||
| U044C - Invalid Data Received From Hybrid/EV Battery Inductive Charging Module | Data bus error value received from control module for contact-less charging | Information content wireless HV charging module | = interlock | [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous | 870 | [ms] | 1 DCY | |
| U0413 - Invalid Data Received From Battery Energy Control Module "B" | Data bus error value received from Battery Energy Control Module "B" | Information content HV battery | = interlock | [-] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 920 | [ms] | 1 DCY | |
| U0599 - Invalid Data Received From DC/DC Converter Control Module "A" | Implausible signal received from DC/DC Converter Control Module "A" | DC/DC converter error state signal | = Interlock | [-] [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous continuous | 470 1.620 | [ms] [ms] | 1 DCY | |
| U0411 - Invalid Data Received From Drive Motor Control Module "A" | Data bus error value received from Drive Motor Control Module "A" | Information content power electronics | = interlock | [-] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 870 | [ms] | 1 DCY | |
| U049C - Invalid Data Received From Battery Charger Control Module "A" | Data bus error value received from Battery Charger Control Module "A" | Information content HV charger | = interlock | [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous | 870 | [ms] | 1 DCY | |
| U0413 - Invalid Data Received From Battery Energy Control Module "B" | Data bus error value received from Battery Energy Control Module "B" | Information content HV battery | = error | [-] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 5.370 | [ms] | 1 DCY | |
| U049C - Invalid Data Received From Battery Charger Control Module "A" | Data bus error value received from Battery Charger Control Module "A" | Information content HV charger | = error | [-] | (Ignition OR Autonomous HV request) HV charging mode Driving mode | = on = commanded on = active = not active | [-] [-] [-] [-] | continuous | 5.370 | [ms] | 1 DCY | |
| U0413 - Invalid Data Received From Battery Energy Control Module "B" | Data bus error value received from Battery Energy Control Module "B" | Information content HV battery | = invalid voltage value | [V] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 2.370 | [ms] | 1 DCY | |
| U0411 - Invalid Data Received From Drive Motor Control Module "A" | Data bus error value received from Drive Motor Control Module "A" | Information content HV converter | = invalid voltage value on HV side | [V] | Ignition OR | = on | [-] | continuous | 2.370 | [ms] | 1 DCY | |
| Autonomous HV request | = commanded on | [-] | ||||||||||
| Data bus error value received from Drive Motor Control Module "A" | Information content power electronics | = invalid voltage value | [V] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 2.370 | [ms] | 1 DCY | ||
| U044C - Invalid Data Received From Hybrid/EV Battery Inductive Charging Module | Data bus error value received from control module for contact-less charging | Information content wireless HV charging module | = no component function | [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous | 2.370 | [ms] | 1 DCY | |
| U0413 - Invalid Data Received From Battery Energy Control Module "B" | Data bus error value received from Battery Energy Control Module "B" | Information content HV battery | = no component function | [-] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 920 | [ms] | 1 DCY | |
| U0599 - Invalid Data Received From DC/DC Converter Control Module "A" | Implausible signal received from DC/DC Converter Control Module "A" | DC/DC converter error state signal | = none component function | [-] [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous continuous | 470 1.620 | [ms] [ms] | 1 DCY | |
| U049C - Invalid Data Received From Battery Charger Control Module "A" | Data bus error value received from Battery Charger Control Module "A" | Information content HV charger | = no component function | [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous | 1.370 | [ms] | 1 DCY | |
| U0599 - Invalid Data Received From DC/DC Converter Control Module "A" | Implausible signal received from DC/DC Converter Control Module "A" | DC/DC converter error state signal | = defect in active discharge | [-] [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous continuous | 470 1.620 | [ms] [ms] | 1 DCY | |
| U0413 - Invalid Data Received From Battery Energy Control Module "B" | Data bus error value received from Battery Energy Control Module "B" | Information content HV battery | = service disconnect | [-] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 920 | [ms] | 1 DCY | |
| U0599 - Invalid Data Received From DC/DC Converter Control Module "A" | Implausible signal received from DC/DC Converter Control Module "A" | DC/DC converter error state signal | = service disconnect | [-] [-] | (Ignition OR Autonomous HV request) Driving mode | = on = commanded on = not active | [-] [-] [-] | continuous continuous | 470 1.620 | [ms] [ms] | 1 DCY | |
| U0413 - Invalid Data Received From Battery Energy Control Module "B" | Data bus error value received from Battery Energy Control Module "B" | Absolute difference between the voltage measured at HV battery and the HV side voltage measured at voltage converter | > 100 | [V] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 3.370 | [ms] | 1 DCY | |
| U0411 - Invalid Data Received From Drive Motor Control Module "A" | Data bus error value received from Drive Motor Control Module "A" | Absolute difference between the voltage measured at HV battery and the HV side voltage measured at voltage converter | > 100 | [V] | Ignition OR Autonomous HV request | = on = commanded on | [-] [-] | continuous | 3.370 | [ms] | 1 DCY | |
| Gateway internal control module | U0447 - Invalid Data Received From Serial Data Gateway Module "A" | Invalid data received from Gateway "A" (EEPROM error) | CASE 1: Read pattern Timer CASE 2: Read pattern Write pattern Timer | = not successful > 5 = successful = not successful > 5 | [-] [s] [-] [-] [s] | ECU active | [-] | once/DCY | 500 | [ms] | 1 DCY | |
| Invalid data received from Gateway "A" (RAM error) | Checksum error | = detected | [-] | ECU active | [-] | multiple | 5.000 | [ms] | 1 DCY | |||
| Invalid data received from Gateway "A" (ROM error) | Checksum error | = detected | [-] | ECU active | [-] | multiple | 5.000 | [ms] | 1 DCY | |||
| Invalid data received from Gateway "A" (watchdog error) | SBC test (External reset OR Watchdog trigger) | = passed != detected != reported by the SBC | [-] [-] [-] | ECU active | [-] | continuous | 5.000 | [ms] | 1 DCY | |||
| Invalid data received from Gateway "A" (vehicle option error) | Coding does not match the actual installation | = detected | [-] | Hybrid vehicle AND LV LiIon starter battery AND Ignition AND | = detected = detected = off | [-] | continuous | 0 | [ms] | 1 DCY | ||
| GW active | = true |
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.