| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold value | Unit | Secondary Parameters | Enable Condition | Unit | Monitor (Frequency of Checks) | Monitoring Time Length | Unit | MIL Illum. |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CAN communication | U0146 - Lost Communication With Serial Data Gateway Module "A" | Lost Communication With Gateway "A" (time out) | Message time out | [-] | Ignition on | > 500 | [ms] | Continuous | 5.000 | [ms] | 2 DCY | |
| Data length | = invalid | [-] | ||||||||||
| U0116 - Lost Communication With Coolant Temperature Control Module | Lost Communication With Coolant Temperature Control Module (time out) | Message time out | [-] | Ignition on | > 500 | [ms] | Continuous | 5.000 | [ms] | 2 DCY | ||
| Data length | = invalid | [-] | ||||||||||
| U0447 - Invalid Data Received From Serial Data Gateway Module "A" | Gateway plausibility fault | Information content | = not plausible | [-] | Ignition on | > 500 | [ms] | Continuous | 500 | [ms] | 2 DCY | |
| U0028 - Vehicle Communication Bus A | Vehicle Communication Bus A | Three unsuccessful transmissions in a row | [-] | None | None | [-] | other event | n/a | [-] | 2 DCY | ||
| U0029 - Vehicle Communication Bus A Performance | Vehicle Communication Bus A Performance | Global message time out | [-] | Ignition on | > 500 | [ms] | Continuous | 450 | [ms] | 2 DCY | ||
| U0447 - Invalid Data Received From Serial Data Gateway Module "A" | Invalid data received from gateway "A" | Information content | = invalid | [-] | Ignition on | > 500 | [ms] | Continuous | 150 | [ms] | 2 DCY | |
| U0456 - Invalid Data Received From Coolant Temperature Control Module | Invalid data received from coolant temperature control module | Information content | = invalid | [-] | Ignition on | > 500 | [ms] | Continuous | 1.500 | [ms] | 2 DCY | |
| Control module for pwr | ||||||||||||
| electronic, output | P33D7 - Control module for pwr electronic output module 1 internal malfunction | Inverter U phase opened | | U phase current DC component | | > 70.27 | [A] | CPLD switching mode | = PWM | [-] | Continuous | 80 | [ms] | 1 DCY |
| module 1 | ||||||||||||
| Ignition | = on | [-] | ||||||||||
| Drive motor speed | > 2, 500.. 5, 500 | [rpm] | ||||||||||
| Drive motor torque | > 20 | [Nm] | ||||||||||
| HV voltage | ≥ 150 | [V] | ||||||||||
| Inverter V phase opened | | V phase current DC component | | > 70.27 | [A] | CPLD switching mode | = PWM | [-] | Continuous | 80 | [ms] | 1 DCY | ||
| Ignition | = on | [-] | ||||||||||
| Drive motor speed | > 2, 500.. 5, 500 | [rpm] | ||||||||||
| Drive motor torque | > 20 | [Nm] | ||||||||||
| HV voltage | ≥ 150 | [V] | ||||||||||
| Inverter W phase opened | | W phase current DC component | | > 70.27 | [A] | CPLD switching mode | = PWM | [-] | Continuous | 80 | [ms] | 1 DCY | ||
| Ignition | = on | [-] | ||||||||||
| Drive motor speed | > 2, 500.. 5, 500 | [rpm] | ||||||||||
| Drive motor torque | > 20 | [Nm] | ||||||||||
| HV voltage | ≥ 150 | [V] | ||||||||||
| Hardware fault | Drive motor inverter current | > 2, 635 | [A] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 50 | [ms] | 1 DCY | ||
| OR | ||||||||||||
| Drive motor inverter temperature | > 174 | [°C] | ||||||||||
| OR | ||||||||||||
| Gate driver power supply | < 20 | [V] | ||||||||||
| Inverter initial HW check fault | Inverter signal at startup | = failed | [-] | HV voltage | < 13 | [V] | Continuous | 50 | [ms] | 1 DCY | ||
| Control module processor | P0606 - Control Module Processor | ECU error: ROM check | Checksum error | [-] | None | None | [-] | Instantly | 1 DCY | |||
| ECU error: analog digital converter check | Error is detected in one of the following ADC tests: | [-] | None | None | [-] | once / DCY | 1 DCY | |||||
| Broken wire monitoring | = failed | |||||||||||
| Pull-Down monitoring | = failed | |||||||||||
| Converter monitoring | = failed | |||||||||||
| ECU error: Program flow check | API calling within the predetermined time | = failed | [-] | None | None | [-] | Instantly | 1 DCY | ||||
| ECU error: Program flash ROM and RAM check | Checksum error | [-] | None | None | [-] | Instantly | 1 DCY | |||||
| ECU error: Processor check | Lock step dual core (LSDC) monitoring | =failed | [-] | None | None | [-] | Instantly | 1 DCY | ||||
| ECU error: Controller RAM check | Checksum error | [-] | None | None | [-] | Instantly | 1 DCY | |||||
| ECU error: Controller configuration register check | Configuration register set value and its read back | = mismatch | [-] | None | None | [-] | Instantly | 1 DCY | ||||
| System controller monitoring | System bus error | [-] | None | None | [-] | Instantly | 1 DCY | |||||
| OR | ||||||||||||
| Clock error | [-] | |||||||||||
| OR | ||||||||||||
| Voltage error | [-] | |||||||||||
| OR | ||||||||||||
| Internal watchdog error | [-] | |||||||||||
| Peripheral startup monitoring | CRC instruction error | = detected | [-] | None | None | [-] | once / DCY | 1 DCY | ||||
| OR | ||||||||||||
| Reset status error | = detected | [-] | ||||||||||
| Cyclic peripheral monitoring | STM timer error | = detected | [-] | None | None | [-] | Instantly | 1 DCY | ||||
| OR | ||||||||||||
| LMU read/write check error | = detected | [-] | ||||||||||
| OR | ||||||||||||
| Interrupt error | = detected | [-] | ||||||||||
| Safe Tlib SW monitoring | Safe Tlib SW monitoring | = failed | [-] | None | None | [-] | once / DCY | 1 DCY | ||||
| Bus memory / register access protection | Illegal write access to CPU resource from other masters | = detected | [-] | None | None | [-] | Instantly | 1 DCY | ||||
| External watchdog monitoring | External watchdog timer communication | = failed | [-] | None | None | [-] | Continuous | 192 | [ms] | 1 DCY | ||
| Shutoff path test for DCDC | Shutoff path test for DCDC | = failed | [V] | Shutoff path test monitoring | = ready to be done | [-] | Continuous | 5 | [ms] | 2 DCY | ||
| [V] | Previous microprocessor shutdown | = successfully | [-] | |||||||||
| = Standby | ||||||||||||
| OR | ||||||||||||
| (Derating by transformer estimated temperature | = detected | = HvOn | ||||||||||
| Backup current plausibility fault | OR | [-] | DCDC Current state | OR | [-] | Continuous | 150 | [ms] | 2 DCY | |||
| Derating by HV voltage) | = detected | = Buck | ||||||||||
| OR | ||||||||||||
| = Error | ||||||||||||
| AND | ||||||||||||
| (| reserve current - estimated reserve current |) | > 255 | [A] | ||||||||||
| OR | ||||||||||||
| (Derating by transformer estimated temperature | ||||||||||||
| OR | = not detected | [-] | ||||||||||
| Derating by HV voltage) | ||||||||||||
| AND | ||||||||||||
| (| reserve current - estimated reserve current |) | > 60.0 | [A] | ||||||||||
| DCDC state plausibility fault | Internal state comparison of safety and quality management | = failed | [-] | Shut off path test | = finished | [-] | Continuous | 140 | [ms] | 2 DCY | ||
| Time elapse after DCDC current state or DCDC estimated state has changed | > 1, 000 | [ms] | ||||||||||
| ECU Error by Level 3 ext. Monitor | Level 3 Shut off path test failed | > 4 | [-] | None | None | [-] | Continuous | 5 | [ms] | 1 DCY | ||
| Control pilot | P0CF5 - Control Pilot Circuit Low | Circuit low | Control pilot voltage | < 0.038 | [V] | None | None | [-] | Continuous | 40 | [ms] | 1 DCY |
| P0CF3 - Control Pilot Circuit /Open | Open circuit | Control pilot voltage | ≥ 0.038 ≤ 2.60 | [V] | None | None | [-] | Continuous | 50 | [ms] | 1 DCY | |
| P0CF6 - Control Pilot Circuit High | Circuit high | Control pilot voltage | > 4.67 | [V] | None | None | [-] | Continuous | 40 | [ms] | 1 DCY | |
| Out of range high | Control pilot voltage | ≥ 3.92 | [V] | None | None | [-] | Continuous | 50 | [ms] | 2 DCY | ||
| = Standby | ||||||||||||
| OR | ||||||||||||
| = HvOn | ||||||||||||
| DC/DC converter | P0D33 - DC/DC Converter Current High | Current high on HV side (HW) | HV current on HW comparator | ≥ 44.6 | [A] | DCDC Current state | OR | [-] | Continuous | 140 | [ms] | 2 DCY |
| = Buck | ||||||||||||
| OR | ||||||||||||
| = Error | ||||||||||||
| = Standby | ||||||||||||
| OR | ||||||||||||
| = HvOn | ||||||||||||
| Current high on HV side (DSP) | HV current on DSP | ≥ 25 | [A] | DCDC Current state | OR | [-] | Continuous | 150 | [ms] | 2 DCY | ||
| = Buck | ||||||||||||
| OR | ||||||||||||
| = Error | ||||||||||||
| = Standby | ||||||||||||
| OR | ||||||||||||
| = HvOn | ||||||||||||
| Current high on positive LV side (HW) | LV current on HW comparator positive | ≥ 342 | [A] | DCDC Current state | OR | [-] | Continuous | 130 | [ms] | 2 DCY | ||
| = Buck | ||||||||||||
| OR | ||||||||||||
| = Error | ||||||||||||
| = Standby | ||||||||||||
| OR | ||||||||||||
| = HvOn | ||||||||||||
| Current high on LV side (DSP) | LV current on DSP | ≥ 335 | [A] | DCDC Current state | OR | [-] | Continuous | 140 | [ms] | 2 DCY | ||
| = Buck | ||||||||||||
| OR | ||||||||||||
| = Error | ||||||||||||
| = Standby | ||||||||||||
| OR | ||||||||||||
| = HvOn | ||||||||||||
| P0D32 - DC/DC Converter "A" Over Temperature | Over temperature on LV side | LV MOSFET temperature | ≥ 120 | [°C] | DCDC Current state | OR | [-] | Continuous | 200 | [ms] | 2 DCY | |
| = Buck | ||||||||||||
| OR | ||||||||||||
| = Error | ||||||||||||
| = Standby | ||||||||||||
| OR | ||||||||||||
| = HvOn | ||||||||||||
| Over temperature on HV side | HV MOSFET temperature | ≥ 130 | [°C] | DCDC Current state | OR | [-] | Continuous | 200 | [ms] | 2 DCY | ||
| = Buck | ||||||||||||
| OR | ||||||||||||
| = Error | ||||||||||||
| = Standby | ||||||||||||
| OR | ||||||||||||
| = HvOn | ||||||||||||
| Over temperature on transformer | Transformer temperature | ≥ 145 | [°C] | DCDC Current state | OR | [-] | Continuous | 200 | [ms] | 2 DCY | ||
| = Buck | ||||||||||||
| OR | ||||||||||||
| = Error | ||||||||||||
| = Standby | ||||||||||||
| OR | ||||||||||||
| = HvOn | ||||||||||||
| Over temperature on safety switch | Safety switch temperature | ≥ 120 | [°C] | DCDC Current state | OR | [-] | Continuous | 200 | [ms] | 2 DCY | ||
| = Buck | ||||||||||||
| OR | ||||||||||||
| = Error | ||||||||||||
| P0A08 - DC/DC Converter Status Circuit | Over voltage | DSP Power supply voltage filtered value | > 3.5 | [V] | DC/DC Converter monitoring | = passed | [-] | Continuous | 20 | [ms] | 2 DCY | |
| = Standby | ||||||||||||
| OR | ||||||||||||
| ≥ 9.8 | [V] | = HvOn | Depends on | |||||||||
| P33D0 - DC/DC converter LV output voltage low voltage | Under voltage and reverse current on LV side | (DCDC converter voltage sensor 2 | and | DCDC Current state | OR | [-] | Continuous | "Malfunction | [-] | 2 DCY | ||
| < 10.5 | [V] | = Buck | Criteria" | |||||||||
| OR | ||||||||||||
| = Error | ||||||||||||
| AND | LV current sensors plausibility monitoring | = passed | [-] | |||||||||
| DCDC converter current sensor C | < -10 | [A] | ||||||||||
| AND | ||||||||||||
| for a period of time) | > 500 | [ms] | ||||||||||
| OR | ||||||||||||
| ≥ 9.8 | [V] | |||||||||||
| (DCDC converter voltage sensor C | and | |||||||||||
| < 10.5 | [V] | |||||||||||
| AND | ||||||||||||
| DCDC converter current sensor C | < -10 | [A] | ||||||||||
| AND | ||||||||||||
| for a period of time) | > 500 | [ms] | ||||||||||
| OR | ||||||||||||
| ≥ 8.2 | [V] | |||||||||||
| (DCDC converter voltage sensor 2 | and | |||||||||||
| < 9.8 | [V] | |||||||||||
| AND | ||||||||||||
| DCDC converter current sensor C | < -10 | [A] | ||||||||||
| AND | ||||||||||||
| for a period of time) OR (DCDC converter voltage sensor C AND DCDC converter current sensor C AND for a period of time) OR (DCDC converter voltage sensor 2 AND DCDC converter current sensor C AND for a period of time) OR (DCDC converter voltage sensor C AND DCDC converter current sensor C AND for a period of time) OR (DCDC converter voltage sensor 2 AND DCDC converter current sensor C AND for a period of time) | > 200 ≥ 8.2 and < 9.8 < -10 > 200 ≥ 7.5 and < 8.2 < -10 > 50 ≥ 7.5 and < 8.2 < -10 > 50 < 7.5 < -10 > 0.2 | [ms] [V] [V] [A] [ms] [V] [V] [A] [ms] [V] [V] [A] [ms] [V] [V] [A] [ms] | ||||||||||
| OR (DCDC converter voltage sensor C AND DCDC converter current sensor C AND for a period of time) | < 7.5 < -10 > 0.2 | [V] [V] [A] [ms] | ||||||||||
| P33CF - DC/DC converter LV output voltage excessive voltage | Over voltage on LV side | (DCDC converter voltage sensor 2 AND DCDC converter current sensor "C" AND for a period of time) OR (DCDC converter voltage sensor 1 AND DCDC converter current sensor "C" AND for a period of time) OR (DCDC converter voltage sensor 2 AND DCDC converter current sensor "C" AND for a period of time) OR | > 16.5 and ≤ 17.0 > 10 > 500 > 17.3 and ≤ 17.8 > 10 > 500 > 17 and ≤ 18 > 10 > 200 | [V] [V] [A] [ms] [V] [V] [A] [ms] [V] [V] [A] [ms] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | Depends on "Malfunction Criteria" | [-] | 2 DCY | |
| (DCDC converter voltage sensor 1 AND DCDC converter current sensor "C" AND for a period of time) OR (DCDC converter voltage sensor 2 AND DCDC converter current sensor "C" AND for a period of time) OR (DCDC converter voltage sensor 1 AND DCDC converter current sensor "C" AND for a period of time) OR (DCDC converter voltage sensor 2 AND DCDC converter current sensor "C" AND for a period of time) OR (DCDC converter voltage sensor 1 | > 17.8 and ≤ 18.8 > 10 > 200 > 18 and ≤ 19.5 > 10 > 50 > 18.8 and ≤ 20.3 > 10 > 50 > 19.5 > 10 > 0.2 > 20.3 | [V] [V] [A] [ms] [V] [V] [A] [ms] [V] [V] [A] [ms] [V] [V] [A] [ms] [V] [V] | ||||||||||
| AND DCDC converter current sensor "C" AND for a period of time) | > 10 > 0.2 | [A] [ms] | ||||||||||
| P0E57 - DC/DC Converter Input Voltage Too High | HV side Input voltage too high | HV voltage | > 490 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 105 | [ms] | 2 DCY | |
| P0A94 - DC/DC Converter "A" Performance | Voltage high on clamp capacitor | Clamp capacitor voltage | ≥ 95 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 280 | [ms] | 2 DCY | |
| P0A08 - DC/DC Converter Status Circuit | Under voltage | DSP Power supply voltage filtered value | < 3.1 | [V] | DC/DC Converter monitoring | = passed | [-] | Continuous | 20 | [ms] | 2 DCY | |
| P33CE - DC/DC converter LV voltage implausible | LV battery plus open | CASE 1: LV battery voltage - LV voltage value AND LV battery voltage - 2x (DC/DC converter voltage sensor 3) CASE 2: | LV voltage value - LV battery voltage | AND | 2x (DC/DC converter voltage sensor 3) - LV battery voltage | | > 3.0 > 3.0 > 3.0 > 3.0 | [V] [V] [V] [V] | CASE 1: DCDC Current state CASE 2: DCDC Current state LV Battery plus diagnosis | = Standby OR = HvOn OR = Error = Buck = not completed | [-] [-] [-] | Continuous | 400 | [ms] | 2 DCY | |
| P0D33 - DC/DC Converter Current High | Current high on HV side | DC/DC converter current sensor "A" | > 25 | [A] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 120, 2 | [ms] | 2 DCY | |
| P0E56 - DC/DC Converter Input Voltage Too Low | Under voltage on HV side | DC/DC converter voltage sensor "A" | < 200 | [V] | Desired DCDC Current state Bus signal received state monitoring | = Buck = passed | [-] [-] | Continuous | 1.000 | [ms] | 2 DCY | |
| P0A08 - DC/DC Converter Status Circuit | Voltage sensor 1 short to battery | | DC/DC converter voltage sensor 1 - DC/DC converter voltage sensor "C" | AND DC/DC converter voltage sensor "C" | ≤ 1.12 > 5.2 | [V] [V] | DCDC Current state | = HvOn OR = Buck OR = Error | [-] | Continuous | 160 | [ms] | 2 DCY | |
| Voltage sensor 3 short to ground | DC/DC converter voltage sensor 3 AND DC/DC converter voltage sensor 1 | ≤ 0.1 > 2.3 | [V] [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 150 | [ms] | 2 DCY | ||
| Voltage sensor 3 short to battery | | DC/DC converter voltage sensor 3 - DC/DC converter voltage sensor 1 | AND DC/DC converter voltage sensor 1 | ≤ 1.74 > 5.2 | [V] [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 160 | [ms] | 2 DCY | ||
| DC/DC converter current sensor "A" | P0E54 - DC/DC Converter Current Sensor "A" Circuit High | Circuit high | DC/DC Converter Current Sensor "A" AD voltage | ≥ 3.2 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 30 | [ms] | 2 DCY |
| P0E53 - DC/DC Converter Current Sensor "A" Circuit Low | Circuit low | DC/DC Converter Current Sensor "A" AD voltage | ≤ 0.1 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 30 | [ms] | 2 DCY | |
| P0E52 - DC/DC Converter Current Sensor "A" Circuit Range/Performance | DCDC HV current out of range low | HV current before filtering | < - 10 | [A] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 40 | [ms] | 2 DCY | |
| DC/DC converter current sensor "B" | P0E9E - DC/DC Converter Current Sensor "B" Circuit High | Circuit high | DC/DC converter current sensor "B" AD voltage | ≥ 2.9 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 50 | [ms] | 2 DCY |
| P0E9D - DC/DC Converter Current Sensor "B" Circuit Low | Circuit low | DC/DC converter current sensor "B" AD voltage | ≤ 0.1 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 50 | [ms] | 2 DCY | |
| P0E9C - DC/DC Converter Current Sensor "B" Circuit Range/Performance | Plausibility fault | | Calculation 1 - constant 1 | (see technical description) | > calculation 2 | [A] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 150 | [ms] | 2 DCY | |
| P0E9E - DC/DC Converter Current Sensor "B" Circuit High | Out of range high | DC/DC Converter Current Sensor "B" | > 20 | [A] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 100 | [ms] | 2 DCY | |
| P0E9D - DC/DC Converter Current Sensor "B" Circuit Low | Out of range low | DC/DC Converter Current Sensor "B" | < - 20 | [A] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 100 | [ms] | 2 DCY | |
| DC/DC converter current sensor "C" | P0EA3 - DC/DC Converter Current Sensor "C" Circuit High | Circuit high | DC/DC Converter Current Sensor "C" A/D voltage value | ≥ 4.9 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 30 | [ms] | 2 DCY |
| P0EA2 - DC/DC Converter Current Sensor "C" Circuit Low | Circuit low | DC/DC Converter Current Sensor "C" A/D voltage value | ≤ 0.1 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 30 | [ms] | 2 DCY | |
| P0EA1 - DC/DC Converter Current Sensor "C" Circuit Range/Performance | Plausibility fault | | DC/DC Converter Current Sensor "C" - LV estimated current | | > 75 | [A] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 110 | [ms] | 2 DCY | |
| DC/DC converter temperature sensor "A" | P0C3B - DC/DC Converter Temperature Sensor "A" High | Circuit high | DC/DC Converter Temperature Sensor "A" A/D voltage value | ≥ 4.9 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 30 | [ms] | 2 DCY |
| P0C3A - DC/DC Converter Temperature Sensor "A" Low | Circuit low | DC/DC Converter Temperature Sensor "A" A/D voltage value | ≤ 0.10 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 30 | [ms] | 2 DCY | |
| DC/DC converter temperature sensor "B" | P0C3D - DC/DC Converter Temperature Sensor "B" Circuit | Plausibility fault | | Transformator temperature - Estimated transformator temperature | | ≥ 35 | [°C] | DCDC Current state Elapse time after switching ignition from off to on | = Standby OR = HvOn OR = Buck OR = Error > 1000 | [-] [ms] | Continuous | 120 | [ms] | 2 DCY |
| Estimated transformer temperature out of range | Transformer estimated temperature OR | ≥ 150 | [°C] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 110 | [ms] | 2 DCY | ||
| Transformer estimated temperature | ≤ - 40 | [°C] | ||||||||||
| P0C40 - DC/DC Converter Temperature Sensor "B" High | Circuit high | DC/DC Converter Temperature Sensor "B" A/D voltage value | ≥ 4.9 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 30 | [ms] | 2 DCY | |
| P0C3F - DC/DC Converter Temperature Sensor "B" Low | Circuit low | DC/DC Converter Temperature Sensor "B" A/D voltage value | ≤ 0.10 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 30 | [ms] | 2 DCY | |
| DC/DC converter temperature sensor "C" | P0E5B - DC/DC Converter Temperature Sensor "C" Circuit High | Circuit high | DC/DC Converter Temperature Sensor "C" A/D voltage value | ≥ 4.9 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 30 | [ms] | 2 DCY |
| P0E5A - DC/DC Converter Temperature Sensor "C" Circuit Low | Circuit low | DC/DC Converter Temperature Sensor "C" A/D voltage value | ≤ 0.10 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 30 | [ms] | 2 DCY | |
| DC/DC converter temperature sensor "D" | P2C8F - DC/DC Converter Temperature Sensor "D" Circuit High | Circuit high | DC/DC Converter Temperature Sensor "D" A/D voltage value | ≥ 4.9 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 30 | [ms] | 2 DCY |
| P2C8E - DC/DC Converter Temperature Sensor "D" Circuit Low | Circuit low | DC/DC Converter Temperature Sensor "D" A/D voltage value | ≤ 0.10 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 30 | [ms] | 2 DCY | |
| DC/DC converter temperature sensors | P0C39 - DC/DC Converter Temperature Sensor "A" Range/Performance | Temperature plausibility fault (crosscheck), sensors comparison | (Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "A" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up OR | > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 | [°C] [°C] [°C] [°C] [°C] | Ignition Previous microprocessor shutdown Elapsed time after ignition on | = on = successfully > 68 | [-] [-] [min] | Continuous | 40 | [ms] | 2 DCY |
| Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up) AND Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "A" temperature stored value at start up AND Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up AND Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up AND Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up | > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 16.2 > 14 > 14 > 14 | [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] | ||||||||||
| P0C3E - DC/DC Converter Temperature Sensor "B" Range/Performance | Temperature plausibility fault (crosscheck), sensors comparison | (Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "A" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR | > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 | [°C] [°C] [°C] [°C] | Ignition Previous microprocessor shutdown Elapsed time after ignition on | = on = successfully > 68 | [-] [-] [min] | Continuous | 40 | [ms] | 2 DCY | |
| Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up) AND Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up AND Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up AND Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up AND Absolute difference between DC/DC converter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up | > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 16.2 > 14 > 14 > 14 | [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] | ||||||||||
| P0E59 - DC/DC Converter Temperature Sensor "C" Circuit Range/Performance | Temperature plausibility fault (crosscheck), sensors comparison | (Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "A" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR | > 50.. 20 > 50.. 20 > 50.. 20 | [°C] [°C] [°C] | Ignition Previous microprocessor shutdown Elapsed time after ignition on | = on = successfully > 68 | [-] [-] [min] | Continuous | 40 | [ms] | 2 DCY | |
| Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up) AND Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up AND Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up AND Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up AND Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up | > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 16.2 > 14 > 14 > 14 | [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] | ||||||||||
| P2C8D - DC/DC Converter Temperature Sensor "D" Circuit Range/Performance | Temperature plausibility fault (crosscheck), sensors comparison | (Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "A" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up OR | > 50.. 20 > 50.. 20 | [°C] [°C] | Ignition Previous microprocessor shutdown Elapsed time after ignition on | = on = successfully > 68 | [-] [-] [min] | Continuous | 40 | [ms] | 2 DCY | |
| Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up) AND Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up AND Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up AND Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up AND Absolute difference between DC/DC converter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up | > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 16.2 > 14 > 14 > 14 | [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] | ||||||||||
| DC/DC converter voltage sensor "A" | P0E34 - DC/DC Converter Voltage Sensor "A" High | Circuit high | DC/DC Converter Voltage Sensor "A" A/D voltage value | ≥ 4.9 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 30 | [ms] | 2 DCY |
| P0E33 - DC/DC Converter Voltage Sensor "A" Low | Circuit low | DC/DC Converter Voltage Sensor "A" A/D voltage value AND Drive motor inverter voltage sensor "A" measured value | ≤ 0.1 > 32.7 | [V] [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 30 | [ms] | 2 DCY | |
| P0E32 - DC/DC Converter Voltage Sensor "A" Range/Performance | Plausibility fault | | Estimated DC/DC Converter voltage Sensor "A" voltage value - DC/DC Converter voltage Sensor "A" voltage value | | > 43.63 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 100 | [ms] | 1 DCY | |
| DC/DC converter voltage sensor "B" | P0E39 - DC/DC Converter Voltage Sensor "B" High | Circuit high | DSP clamp capacitor voltage | ≥ 2.9 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 150 | [ms] | 2 DCY |
| P0E38 - DC/DC Converter Voltage Sensor "B" Low | Circuit low | DC/DC Converter Voltage Sensor "B" A/D voltage AND DC/DC Converter Voltage Sensor "C" | ≤ 0.1 > 5.6 | [V] [V] | DCDC Current state time elapse after safety switch is turned from OFF to ON | = HvOn OR = Buck OR = Error > 50 | [-] [ms] | Continuous | 150 | [ms] | 2 DCY | |
| P0E37 - DC/DC Converter Voltage Sensor "B" Range/Performance | Plausibility fault | CASE 1: For H1 PWM duty average value (| DC/DC converter voltage sensor "B" - DC/DC converter voltage sensor "C" | AND | DC/DC converter voltage sensor "B" - 2x (DC/DC converter voltage sensor 1) |) CASE 2: For H1 PWM duty average value OR | = 0 > 1.5 > 3.72 != 0 | [-] [V] [V] [-] | DCDC Current state Elapsed time after DC/DC PWM was stopped DC/DC converter voltage sensor "A" circuit low monitoring | = Standby OR = HvOn OR > 60 = passed | [-] [ms] [-] | Continuous | 200 | [ms] | 2 DCY | |
| (| DC/DC converter voltage sensor "B" - HV voltage | AND | DC/DC converter voltage sensor "B" - HV redundant voltage |) | > 23.32 > 36.54 | [V] [V] | ||||||||||
| DC/DC converter voltage sensor "C" | P0E99 - DC/DC Converter Voltage Sensor "C" Circuit High | Circuit high | DC/DC Converter Voltage Sensor "C" A/D voltage | ≥ 4.9 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 30 | [ms] | 2 DCY |
| P0E98 - DC/DC Converter Voltage Sensor "C" Circuit Low | Circuit low | DC/DC Converter Voltage Sensor "C" A/D voltage AND DC/DC converter voltage sensor 1 | ≤ 0.1 ≥ 1.0 | [V] [V] | DCDC Current state Voltage sensor 1 short to battery monitoring | = HvOn OR = Buck OR = Error = Passed | [-] [-] | Continuous | 80 | [ms] | 2 DCY | |
| P0E97 - DC/DC Converter Voltage Sensor "C" Circuit Range/Performance | Plausibility fault | Case 1: For safety switches AND DCDC switch | DC/DC converter voltage sensor "C" - 2x (DC/DC converter voltage sensor 1) | | DC/DC converter voltage sensor "C" - DC/DC converter voltage sensor 3 | Case 2: For safety switches OR DCDC switch (DC/DC converter voltage sensor "C" AND DC/DC converter voltage sensor 1) OR DC/DC converter voltage sensor "C" | = on > 1.84 > 2.1 = off > 1.62 ≤ 0.4 > 21.74 | [-] [V] [V] [-] [V] [V] [V] | DCDC Current state Elapse time after PWM duty has changed Voltage sensor 1 short to battery monitoring | = Standby OR = HvOn OR = Buck OR = Error > 50 = Passed | [-] [ms] [-] | Continuous | 110 | [ms] | 2 DCY | |
| DC/DC converter voltage sensor 1 | P32A5 - DC/DC converter voltage sensor 1 Short circuit to B+ | Short to battery | DC/DC converter voltage sensor 1 A/D voltage | ≥ 3.2 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 30 | [ms] | 2 DCY |
| P32A6 - DC/DC converter voltage sensor 1 Short circuit to Ground (GND) | Short to ground | DC/DC converter voltage sensor 1 AD voltage | ≤ 0.1 | [V] | DCDC Current state | = HvOn OR = Buck OR = Error | [-] | Continuous | 100 | [ms] | 2 DCY | |
| AND DC/DC converter voltage sensor "C" AD voltage | > 2.74 | [V] | ||||||||||
| P32A7 - DC/DC converter voltage sensor 1 Range/Performance | Out of range high | DC/DC converter voltage sensor 1 voltage | > 15 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 40 | [ms] | 2 DCY | |
| DC/DC converter voltage sensor 2 | P32AA - DC/DC converter voltage sensor 2 Short circuit to B+ | Short to battery | DC/DC converter voltage sensor 2 AD voltage | ≥ 4.9 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 30 | [ms] | 2 DCY |
| P32AB - DC/DC converter voltage sensor 2 Short circuit to Ground (GND) | Short to ground | DC/DC converter voltage sensor 2 AD voltage AND DC/DC converter voltage sensor 3 | ≤ 0.1 > 1.0 | [V] [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 30 | [ms] | 2 DCY | |
| P32AC - DC/DC converter voltage sensor 2 Range/Performance | Plausibility fault | CASE 1: | DC/DC converter voltage sensor 2 - 2x (DC/DC converter voltage sensor 3) | AND | DC/DC converter voltage sensor 2 - DC/DC converter voltage sensor "C" | CASE 2: | DC/DC converter voltage sensor 2 - 2x (DC/DC converter voltage sensor 3) | AND | DC/DC converter voltage sensor 2 - Terminal 30 voltage | | > 3.18 > 2.26 > 3.18 > 1.76 | [V] [V] [V] [V] | DCDC Current state Only for CASE 1: safety switches AND DCDC Switching Only for CASE 2: safety switches OR DCDC Switching | = Standby OR = HvOn OR = Buck OR = Error = on = on = off = off | [-] [-] [-] [-] [-] | Continuous | 100 | [ms] | 2 DCY | |
| DC/DC converter voltage sensor 3 | P32AF - DC/DC converter voltage sensor 3 Short circuit to B+ | Short to battery | DC/DC converter voltage sensor 3 AD value | ≥ 4.9 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 30 | [ms] | 2 DCY |
| P32B1 - DC/DC converter voltage sensor 3 Range/Performance | Out of range high | DC/DC converter voltage sensor 3 | > 16.6 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 40 | [ms] | 2 DCY | |
| Drive motor | P0C01 - Drive Motor "A" Current High | Current high | | AC current | | ≥ 900 | [A] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 60 | [ms] | 2 DCY |
| P0A2F - Drive Motor "A" Over Temperature | Stator over temperature | Drive motor stator temperature | ≥ 205 | [°C] | Drive mode Range switch of drive motor temperature sensor | != Standby Restart processing OR != Init. OR != Standby post run = initialized | [-] [-] [-] [-] | Continuous | 1.000 | [ms] | 2 DCY | |
| P0C4E - Drive Motor "A" Position Exceeded Learning Limit | Drive motor position exceeded learning limit | Angle offset Counter for angle offset out of range | = out of range > 3 | [-] [-] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 5 | [ms] | 2 DCY | |
| P0A90 - Drive Motor "A" Performance | Performance fault | Drive motor efficiency monitoring | = failed | [-] | Drive mode Drive motor speed Drive motor torque | = Normal torque control > 500 < 7000 > 75 < 500 | - [-] [rpm] [Nm] | Continuous | 180.000 | [ms] | 2 DCY | |
| P0A2F - Drive Motor "A" Over Temperature | Rotor over temperature | Rotor temperature | > 155 | [°C] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 10.000 | [ms] | 2 DCY | |
| Drive motor control module | P0A1B - Drive Motor "A" Control Module Performance | Vaux 5 V out of range | Vaux 5 V OR Vaux 5 V | < 4.63 +/-0.125 > 5.38 +/-0.125 | [V] [V] | None | None | [-] | Continuous | 0.234 | [ms] | 1 DCY |
| Vcore 3.3 V out of range | Vaux 3.3 V OR Vaux 3.3 V | < 2.82 +/-0.20 > 3.74 +/-0.14 | [V] [V] | None | None | [-] | Continuous | 0.234 | [ms] | 1 DCY | ||
| Power supply for ADC and drive motor inverter temperature sensor "B" out of range | Vcc 5 V OR Vcc 5 V | < 4.63 +/-0.125 > 5.38 +/-0.125 | [V] [V] | None | None | [-] | Continuous | 0.234 | [ms] | 1 DCY | ||
| FlexRay driver under voltage | FlexRay driver power supply | < 4.54 | [V] | None | None | [-] | Continuous | 10 | [ms] | 1 DCY | ||
| FlexRay driver over voltage | FlexRay driver power supply | > 5.49 | [V] | None | None | [-] | Continuous | 10 | [ms] | 1 DCY | ||
| Rotor position sensor under voltage | Rotor position sensor power supply | < 4.74 | [V] | None | None | [-] | Continuous | 15 | [ms] | 1 DCY | ||
| Rotor position sensor over voltage | Rotor position sensor power supply | > 5.25 | [V] | None | None | [-] | Continuous | 15 | [ms] | 1 DCY | ||
| Power supply of 6.5V out of range | Power supply of 6.5 V | > 7.6 +/- 0.4 | [V] | None | None | [-] | Continuous | 0.234 | [ms] | 1 DCY | ||
| CAN driver power supply under voltage | CAN driver power supply | < 4.50 | [V] | None | None | [-] | Continuous | 50 | [ms] | 1 DCY | ||
| CAN driver power supply over voltage | CAN driver power supply | > 5.53 | [V] | None | None | [-] | Continuous | 50 | [ms] | 1 DCY | ||
| Gate driver low side under voltage | Gate driver low side voltage | < 4.54 | [V] | None | None | [-] | Continuous | 15 | [ms] | 1 DCY | ||
| Gate driver low side over voltage | Gate driver low side voltage | > 5.49 | [V] | None | None | [-] | Continuous | 15 | [ms] | 1 DCY | ||
| CPLD under voltage | CPLD power supply | < 3.18 | [V] | None | None | [-] | Continuous | 15 | [ms] | 1 DCY | ||
| CPLD over voltage | CPLD power supply | > 3.42 | [V] | None | None | [-] | Continuous | 15 | [ms] | 1 DCY | ||
| Gate driver high side under voltage | Gate drive high side voltage | < 4.54 | [V] | None | None | [-] | Continuous | 15 | [ms] | 1 DCY | ||
| Gate driver high side over voltage | Gate drive high side voltage | > 5.49 | [V] | None | None | [-] | Continuous | 15 | [ms] | 1 DCY | ||
| Reference power supply over voltage | Reference power supply | > 3.04 | [V] | None | None | [-] | Continuous | 20 | [ms] | 1 DCY | ||
| Reference power supply under voltage | Reference power supply | < 2.96 | [V] | None | None | [-] | Continuous | 20 | [ms] | 1 DCY | ||
| Backup 7 V power supply under voltage | Backup 7 V power supply | < 4.87 | [V] | None | None | [-] | Continuous | 10 | [ms] | 1 DCY | ||
| Backup 7 V power supply over voltage | Backup 7 V power supply | > 7.90 | [V] | None | None | [-] | Continuous | 10 | [ms] | 1 DCY | ||
| ECU error: Shutoff paths test | Shutoff path test | = finished AND = failed | [-] | Pre-charge Ignition Shut off path test Monitor test | = finished = on = finished = not completed | [-] [-] [-] [-] | Continuous | 20 | [ms] | 1 DCY | ||
| Drive motor current sensor | P0A54 - Drive Motor "A" Current Sensor Circuit High | High range high fault | Drive motor current sensor AD voltage | > 4.90 | [V] | None | None | [-] | Continuous | 15 | [ms] | 1 DCY |
| P0A53 - Drive Motor "A" Current Sensor Circuit Low | High range low fault | Drive motor current sensor AD voltage | < 0.10 | [V] | None | None | [-] | Continuous | 15 | [ms] | 1 DCY | |
| P0A52 - Drive Motor "A" Current Sensor Circuit Range/Performance | Plausibility fault | | HV DC current - Calculated HV DC current | | > 68 | [A] | CPLD switching mode Ignition Drive motor speed HV voltage | = PWM = on > 550 > 160 | [-] [-] [rpm] [V] | Continuous | 35 | [ms] | 1 DCY | |
| High range offset fault | | DC/DC converter current sensor "A" - HV calculated current | for a period of time | > 10 > 80 | [A] [ms] | Ignition DC current offset calculation Monitor test (CPLD switching mode AND (| Drive motor speed | for a period of time)) HV voltage calculation time out | = on = done = not completed = Free wheel OR = Active short circuit ≤ 10 > 10 >8.75 = false | [-] [-] [-] [-] [rpm] [ms] [V] [-] | Continuous | 5 | [ms] | 1 DCY | ||
| Low range offset fault | | DC/DC converter current sensor "C" - HV calculated current | for a period of time | > 5 > 80 | [A] [ms] | Ignition DC current offset calculation Monitor test (CPLD switching mode AND (| Drive motor speed | for a period of time)) HV voltage | = on = done = not completed = Free wheel OR = Active short circuit ≤ 10 > 10 >8.75 | [-] [-] [-] [-] [rpm] [ms] [V] | Continuous | 5 | [ms] | 1 DCY | ||
| calculation time out | = false | [-] | ||||||||||
| P0A54 - Drive Motor "A" Current Sensor Circuit High | Low range high fault | Drive motor current sensor AD voltage | > 4.90 | [V] | None | None | [-] | Continuous | 15 | [ms] | 1 DCY | |
| P0A53 - Drive Motor "A" Current Sensor Circuit Low | Low range low fault | Drive motor current sensor AD voltage | < 0.10 | [V] | None | None | [-] | Continuous | 15 | [ms] | 1 DCY | |
| Out of range high | Drive motor current sensor current | > 600 | [A] | None | None | [-] | Continuous | 25 | [ms] | 1 DCY | ||
| P0A54 - Drive Motor "A" Current Sensor Circuit High | Out of range low | Drive motor current sensor current | < -600 | [A] | Ignition | None | [-] | Continuous | 25 | [ms] | 1 DCY | |
| Drive motor inverter | P0A3C - Drive Motor "A" Inverter Over Temperature | Over temperature | Drive motor inverter calculated temperature OR Intermediate coolant temperature model calculated value OR IGBT temperature | ≥ 165 ≥ 100 ≥ 156 | [°C] [°C] [°C] | Drive mode (HV voltage OR AC current) | != Standby Restart processing OR != Init. OR != Standby post run ≥ 100 ≥ 50 | [-] [-] [-] [V] [A] | Continuous | 100 | [ms] | 2 DCY |
| P0C79 - Drive Motor "A" Inverter Voltage Too High | Voltage high | Inverter voltage | > 475 ± 10 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 45 | [ms] | 2 DCY | |
| P0A3C - Drive Motor "A" Inverter Over Temperature | X-Capacitor over temperature | X-Capacitor temperature | ≥ 110 | [°C] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 1.000 | [ms] | 2 DCY | |
| AC connector over temperature | AC connector temperature | ≥ 180 | [°C] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 1.000 | [ms] | 2 DCY | ||
| Power module AC terminal over temperature | Power module AC terminal temperature | ≥ 180 | [°C] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 1.000 | [ms] | 2 DCY | ||
| Y- Capacitor over temperature | Y-Capacitor temperature | ≥ 110 | [°C] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 1.000 | [ms] | 2 DCY | ||
| Over temperature on PCB | PCB temperature | ≥ 140 | [°C] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 200 | [ms] | 2 DCY | ||
| Drive motor inverter temperature sensor "A" | P0AEE - Drive Motor Inverter Temperature Sensor "A" Circuit Range/Performance | Plausibility fault | | Drive Motor Inverter Temperature Sensor "A" - DC/DC converter temperature sensor "D" | | > 50.. 20 | [°C] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 200 | [ms] | 1 DCY |
| OR | Drive motor inverter temperature Sensor "A" - Drive motor inverter temperature sensor "B" | | > 50.. 20 | [°C] | Ignition Rest period Previous microprocessor shutdown | on > 100 = successfully | [-] [min] [-] | |||||||
| P0AF0 - Drive Motor Inverter Temperature Sensor "A" Circuit High | Short to battery | Duty cycle temperature sensor | ≥ 89.5 | [%] | Drive mode HV voltage | != Standby Restart processing OR != Init. OR != Standby post run ≥ 60 | [-] [-] [-] [V] | Continuous | 50 | [ms] | 1 DCY | |
| P0AEF - Drive Motor Inverter Temperature Sensor "A" Circuit Low | Short to ground | Duty cycle temperature sensor | ≤ 10.5 | [%] | Drive mode HV voltage | != Standby Restart processing OR != Init. OR != Standby post run ≥ 60 | [-] [-] [-] [V] | Continuous | 50 | [ms] | 1 DCY | |
| Circuit low | Inverter temperature | ≤ -52 | [°C] | Drive mode HV voltage | != Standby Restart processing OR != Init. OR != Standby post run ≥ 60 | [-] [-] [-] [V] | Continuous | 100 | [ms] | 1 DCY | ||
| Drive motor inverter temperature sensor "B" | P0AF5 - Drive Motor Inverter Temperature Sensor "B" Circuit High | Circuit high | Drive Motor Inverter Temperature Sensor "B" A/D voltage value | ≥ 4.9 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 30 | [ms] | 2 DCY |
| P0AF4 - Drive Motor Inverter Temperature Sensor "B" Circuit Low | Circuit low | Drive Motor Inverter Temperature Sensor "B" A/D voltage value | ≤ 0.10 | [V] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 30 | [ms] | 2 DCY | |
| P0AF3 - Drive Motor Inverter Temperature Sensor "B" Circuit Range/Performance | Temperature plausibility fault (crosscheck), sensors comparison | (Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "A" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR | > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 | [°C] [°C] [°C] [°C] | Ignition Previous microprocessor shutdown Rest period | = on = successfully > 68 | [-] [-] [min] | Continuous | 40 | [ms] | 2 DCY | |
| Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up) AND Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "A" temperature stored value at start up AND Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up AND Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up AND Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up | > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 16.2 > 16.2 > 16.2 > 16.2 | [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] | ||||||||||
| Drive motor inverter voltage sensor "A" | P0D30 - Drive Motor "A" Inverter Voltage Sensor "A" Circuit High | Short to battery | Drive motor inverter voltage sensor "A" AD voltage AND HV redundant AD voltage | ≥ 4.90 < 4.14 | [V] [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 25 | [ms] | 1 DCY |
| P0D2E - Drive Motor "A" Inverter Voltage Sensor "A" Circuit Range/Performance | Plausibility fault | | Drive motor Inverter Voltage Sensor "A" voltage physical value - Drive motor Inverter Voltage Sensor "A" redundant voltage value | | > 43.63 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 40 | [ms] | 1 DCY | |
| Drive motor Inverter Voltage Sensor "A" redundant raw value Drive motor Inverter Voltage Sensor "A" redundant raw value | < 4.8 > 0.1 | [V] [V] | ||||||||||
| P0D30 - Drive Motor "A" Inverter Voltage Sensor "A" Circuit High | Out of range high | Drive motor inverter voltage sensor "A" voltage physical value | ≥ 630 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] | Continuous | 30 | [ms] | 1 DCY | |
| P0D2D - Drive Motor "A" Inverter Voltage Sensor "A" Circuit | HV DC offset under voltage | HV DC offset voltage | < 2.00 | [V] | None | None | [-] | Continuous | 20 | [ms] | 1 DCY | |
| HV DC offset over voltage | HV DC offset voltage | > 2.71 | [V] | None | None | [-] | Continuous | 20 | [ms] | 1 DCY | ||
| Drive motor phase U | P0A5D - Drive Motor "A" Phase U Current | Open circuit before operation | U phase current U phase open circuit before operation error counter | < 5.49 > 7 | [A] [-] | Ignition V phase open circuit before operation W phase open circuit before operation Ripoff monitoring Monitor test | = on = passed = passed = competed = not completed | [-] [-] [-] | Continuous | 5 | [ms] | 1 DCY |
| Drive motor phase U current sensor | P0BE6 - Drive Motor "A" Phase U Current Sensor Circuit Range/Performance | Offset fault | | sensor offset phase U | AND for a period of time | > 20.86 > 35 | [A] [ms] | Ignition AC current offset calculation Ripoff monitoring Monitor test (CPLD switching mode AND (| Drive motor speed | for a period of time)) | = on = done = not done yet = not completed = Free wheel OR = Active short circuit ≤ 10 > 10 | [-] [-] [-] [-] [-] [rpm] [ms] | once / DCY | n/a | [ms] | 1 DCY |
| Drive motor phase U-V W | P0C05 - Drive Motor "A" Phase U-V-W Circuit/Open | 2 or 3 phases open circuit before operation | U phase open circuit before operation AND V phase open circuit before operation OR | = failed = failed | [-] [-] | Ignition Ripoff monitoring | = on = competed | [-] [-] | Continuous | 5 | [ms] | 1 DCY |
| U phase open circuit before operation AND W phase open circuit before operation OR V phase open circuit before operation AND W phase open circuit before operation OR U phase open circuit before operation AND V phase open circuit before operation AND W phase open circuit before operation AND Phases open circuit before operation error counter | = failed = failed = failed = failed = failed = failed = failed | [-] [-] [-] [-] [-] [-] [-] | Monitor test | = not completed | [-] | |||||||
| Drive motor phase U-V W current sensor | P0BE8 - Drive Motor "A" Phase U Current Sensor Circuit High | Short to battery | U Phase current AD voltage | ≥ 4.90 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 20 | [ms] | 1 DCY |
| P0BE7 - Drive Motor "A" Phase U Current Sensor Circuit Low | Short to ground | U Phase current AD voltage | ≤ 0.10 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 20 | [ms] | 1 DCY | |
| P0BFD - Drive Motor "A" Phase U-V-W Current Sensor Correlation | Crosscheck drive motor phase current balance U, V, W sensors | AC Current 3 phases sum | ≥ 66.98 | [A] | Drive mode Ignition | != Standby Restart processing OR != Init. OR != Standby post run = on | [-] [-] [-] [-] | Continuous | 25 | [ms] | 1 DCY | |
| P0BEC - Drive Motor "A" Phase V Current Sensor Circuit High | Short to battery | V Phase current AD voltage | ≥ 4.90 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 20 | [ms] | 1 DCY | |
| P0BEB - Drive Motor "A" Phase V Current Sensor Circuit Low | Short to ground | V Phase current AD voltage | ≤ 0.10 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 20 | [ms] | 1 DCY | |
| P0BF0 - Drive Motor "A" Phase W Current Sensor Circuit High | Short to battery | W Phase current AD voltage | ≥ 4.90 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 20 | [ms] | 1 DCY | |
| P0BEF - Drive Motor "A" Phase W Current Sensor Circuit Low | Short to ground | W Phase current AD voltage | ≤ 0.10 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 20 | [ms] | 1 DCY | |
| Drive motor phase V | P0A60 - Drive Motor "A" Phase V Current | Open circuit before operation | V phase current V phase open circuit before operation error counter | < 5.49 > 7 | [-] [-] | Ignition U phase open circuit before operation W phase open circuit before operation | = on = passed = passed | [-] | Continuous | 5 | [ms] | 1 DCY |
| Ripoff monitoring Monitor test | = competed = not completed | [-] [-] | ||||||||||
| Drive motor phase V current sensor | P0BEA - Drive Motor "A" Phase V Current Sensor Circuit Range/Performance | Drive motor phase V current offset fault | | sensor offset phase V | AND time | > 20.86 > 35 | [A] [ms] | Ignition AC current offset calculation Monitor test Ripoff monitoring (CPLD switching mode AND (| Drive motor speed | for a period of time)) | = on = done = not completed = not done yet = Free wheel OR = Active short circuit ≤ 10 > 10 | [-] [-] [-] [-] [-] [rpm] [ms] | once / DCY | n/a | [ms] | 1 DCY |
| Drive motor phase W | P0A63 - Drive Motor "A" Phase W Current | Open circuit before operation | W phase current W phase open circuit before operation error counter | < 5.49 > 7 | [-] [-] | Ignition U phase open circuit before operation V phase open circuit before operation Ripoff monitoring Monitor test | = on = passed = passed = competed = not completed | [-] [-] [-] | Continuous | 5 | [ms] | 1 DCY |
| Drive motor phase W current sensor | P0BEE - Drive Motor "A" Phase W Current Sensor Circuit Range/Performance | Drive motor phase W current offset fault | | sensor offset phase W | AND for a period of time | > 20.86 > 35 | [A] [ms] | Ignition AC current offset calculation Monitor test Ripoff monitoring (CPLD switching mode AND | = on = done = not completed = not done yet = Free wheel OR = Active short circuit | [-] [-] [-] [-] [-] | once / DCY | n/a | [ms] | 1 DCY |
| (|Drive motor speed | for a period of time)) | ≤ 10 > 10 | [rpm] [ms] | ||||||||||
| Drive motor position sensor | P0A3F - Drive Motor "A" Position Sensor Circuit | Sine and Cosine circuit high | SIN and COS position sensor | ≥ 4.43 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 25 | [ms] | 1 DCY |
| Sine and Cosine circuit low | SIN and COS position sensor | ≤ 0.50 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 25 | [ms] | 1 DCY | ||
| P0A40 - Drive Motor "A" Position Sensor Circuit Range/Performance | Sine and Cosine ratio fault | Amplitude difference between SIN and COS | ≥ 22.5 ≤ - 29 | [%] | Drive mode SIN / COS compensation monitoring This diagnosis | != Standby Restart processing OR != Init. OR != Standby post run = completed = has not been done | [-] [-] [-] [-] [-] | Continuous | 75 | [ms] | 1 DCY | |
| Rotor position sensor SIN / COS variation fault | Sum of normalized SIN square and normalized COS square | ≥ 1.28 ≤ 0.71 | [pu] [pu] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 50 | [ms] | 1 DCY | ||
| Rotor position sensor loss of tracking fault | Integrator tracking observer | ≥ 90 | [°] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 50 | [ms] | 1 DCY | ||
| Circuit Range/Performance | | Drive motor speed - Calculated drive motor speed | OR (| Drive motor speed - Calculated drive motor speed | AND |Drive motor speed - Motor speed after cross fade processing|) | ≥ 32, 767 < 50 ≥ 150 | [rpm] [rpm] [rpm] | Ignition | = on | [-] | Continuous | 80 | [ms] | 1 DCY | ||
| P0A44 - Drive Motor "A" Position Sensor Circuit Overspeed | Over speed fault | Drive motor speed | ≤ -1, 210 ≥ 7, 410 | [rpm] [rpm] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 80 | [ms] | 2 DCY | |
| P0C52 - Drive Motor "A" Position Sensor Circuit "A" Low | Signal low | SIN signal position sensor | < 0.34 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 45 | [ms] | 1 DCY | |
| P0C53 - Drive Motor "A" Position Sensor Circuit "A" High | Signal high | SIN signal position sensor | > 4.66 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 45 | [ms] | 1 DCY | |
| Short to battery | SIN position sensor | > 4.90 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] | Continuous | 35 | [ms] | 1 DCY | ||
| P0C52 - Drive Motor "A" Position Sensor Circuit "A" Low | Short to ground | SIN position sensor | < 0.10 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] | Continuous | 35 | [ms] | 1 DCY | |
| P0C5C - Drive Motor "A" Position Sensor Circuit "B" Low | Signal low | COS position sensor | < 0.34 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 45 | [ms] | 1 DCY | |
| P0C5D - Drive Motor "A" Position Sensor Circuit "B" High | Signal high | COS signal position sensor | > 4.66 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 45 | [ms] | 1 DCY | |
| Short to battery | COS signal position sensor | > 4.90 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] | Continuous | 35 | [ms] | 1 DCY | ||
| P0C5C - Drive Motor "A" Position Sensor Circuit "B" Low | Short to ground | COS position sensor | < 0.10 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] | Continuous | 35 | [ms] | 1 DCY | |
| Drive motor temperature sensor | P0A2A - Drive Motor "A" Temperature Sensor "A" Circuit | Diagnosis switch monitoring | Range switch Diagnosis switch voltage absolute difference after switching | = on < 0.5 | [-] [V] | Ignition Monitor test Range switch of drive motor temperature sensor | = on = not completed = initialized | [-] [-] [-] | Continuous | 45 | [ms] | 2 DCY |
| P0A2D - Drive Motor "A" Temperature Sensor "A" Circuit High | Short to battery | Voltage measure drive motor temperature sensor | ≥ 4.70 | [V] | Stator switching temperature Range switch of drive motor temperature sensor | ≤ 75 = initialized | [°C] [-] | Continuous | 15 | [ms] | 2 DCY | |
| P0A2C - Drive Motor "A" Temperature Sensor "A" Circuit Low | Short to ground | Voltage measure drive motor temperature sensor | ≤ 0.10 | [V] | Stator switching temperature Range switch of drive motor temperature sensor | > 75 = initialized | [°C] [-] | Continuous | 15 | [ms] | 2 DCY | |
| P0A2E - Drive Motor "A" Temperature Sensor "A" Circuit Intermittent | Circuit Intermittent | | Drive motor temperature sensor - previous stored drive motor temperature | | > 20 | [°C] | Range switch of drive motor temperature sensor | = initialized | [-] | Continuous | 40 | [ms] | 2 DCY | |
| P0A2B - Drive Motor "A" Temperature Sensor "A" Circuit Range/Performance | Temperature plausibility fault (crosscheck) | | Drive motor Temperature Sensor - Transmission oil temperature | | > 50.. 20 | [°C] | Drive mode Ignition | != Standby Restart processing OR != Init. OR != Standby post run on | [-] [-] [-] [-] | Continuous | 200 | [ms] | 1 DCY | |
| HV voltage off time Previous microprocessor shutdown Time after DMCM wakeup | > 100 = successfully < 4 | [min] [-] [min] | ||||||||||
| P0A2A - Drive Motor "A" Temperature Sensor "A" Circuit | Range switch monitoring | Diagnosis switch Range switch voltage absolute difference after switching | = on < 0.6 | [-] [V] | Ignition Monitor test Range switch of drive motor temperature sensor | = on = not completed = initialized | [-] [-] [-] | Continuous | 45 | [ms] | 2 DCY | |
| P0A2D - Drive Motor "A" Temperature Sensor "A" Circuit High | Out of range low | Motor temperature sensor | ≤ -43.88 | [°C] | Stator switching temperature Range switch of drive motor temperature sensor | ≤ 75 = initialized | [°C] [-] | Continuous | 30 | [ms] | 2 DCY | |
| FlexRay communicaiton | U0112 - Lost Communication With Battery Energy Control Module "B" | Lost Communication With Battery Energy Control Module "B" (time out) | Message time out Data length | = invalid | [-] [-] | Ignition on | > 500 | [ms] | Continuous | 5.000 | [ms] | 1 DCY |
| U0101 - Lost Communication with TCM | Lost Communication with TCM (time out) | Message time out Data length | = invalid | [-] [-] | Ignition on | > 500 | [ms] | Continuous | 800 | [ms] | 2 DCY | |
| U0146 - Lost Communication With Serial Data Gateway Module "A" | Lost Communication With Gateway "A" (time out) | Message time out Data length | = invalid | [-] [-] | Ignition on | > 500 | [ms] | Continuous | 5.000 | [ms] | 2 DCY | |
| U0141 - Lost Communication With Body Control Module "A" | Lost Communication With Body Control Module "A" (time out) | Message time out Data length | = invalid | [-] [-] | Ignition on | > 500 | [ms] | Continuous | 1.000 | [ms] | 2 DCY | |
| U0140 - Lost Communication With Body Control Module | Lost Communication With Body Control Module (time out) | Message time out Data length | = invalid | [-] [-] | Ignition on | > 500 | [ms] | Continuous | 2.000 | [ms] | 2 DCY | |
| U0100 - Lost Communication With ECM/PCM "A" | Lost Communication With ECM/PCM "A" (time out) | Message time out Data length | = invalid | [-] [-] | Ignition on | > 500 | [ms] | Continuous | 5.000 | [ms] | 1 DCY | |
| U0431 - Invalid Data Received From Body Control Module "A" | Body control module "A" plausibility fault | Information content | = not plausible | [-] | Ignition on | > 500 | [ms] | Continuous | 1.000 | [ms] | 2 DCY | |
| U0401 - Invalid Data Received From ECM/PCM "A" | Engine control module "A" plausibility fault | Information content | = not plausible | [-] | Ignition on | > 500 | [ms] | Continuous | 500 | [ms] | 1 DCY | |
| U0080 - Vehicle Communication Bus F | Flex Ray synchronization lost | FlexRay lost synchronization | = transmitting and receiving no message | [-] | Ignition on | > 500 | [ms] | Continuous | 0 | [ms] | 1 DCY | |
| U106E - FlexRay data bus Signal malfunction | Flex Ray transmission collision | FlexRay message | = no feedback | [-] | Ignition on | > 500 | [ms] | Continuous | 0 | [ms] | 1 DCY | |
| U0413 - Invalid Data Received From Battery Energy Control Module "B" | Invalid data received from battery energy control module | Information content | = invalid | [-] | Ignition on | > 500 | [ms] | Continuous | 3.000 | [ms] | 1 DCY | |
| U0402 - Invalid Data Received From TCM | Invalid data received from transmission control module | Information content | = invalid | [-] | Ignition on | > 500 | [ms] | Continuous | 240 | [ms] | 2 DCY | |
| U0447 - Invalid Data Received From Serial Data Gateway Module "A" | Invalid data received from gateway | Information content | = invalid | [-] | Ignition on | > 500 | [ms] | Continuous | 30 | [ms] | 2 DCY | |
| U0422 - Invalid Data Received From Body Control Module | Invalid data received from body control module 1 | Information content | = invalid | [-] | Ignition on | > 500 | [ms] | Continuous | 600 | [ms] | 2 DCY | |
| U0401 - Invalid Data Received From ECM/PCM "A" | Invalid data received from engine control module "A" | Information content | = invalid | [-] | Ignition on | > 500 | [ms] | Continuous | 2.880 | [ms] | 1 DCY | |
| Function restriction | U1400 - Function restriction Function restriction due to low voltage | due to insufficient voltage from power supply | LV battery voltage | > 5.75 < 8.75 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 100 | [ms] | 2 DCY |
| U1401 - Function restriction due to excessive voltage | due to excessive voltage from power supply | LV battery voltage | > 16.375 < 30 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 100 | [ms] | 2 DCY | |
| U141B - Function restriction due to special software | due to special software | Software manipulation | = detected | [-] | None | None | [-] | Continuous | 1.000 | [ms] | 1 DCY | |
| High voltage fuse | P0A95 - High Voltage Fuse "A" | Fuse fault | Fuse open duty | ≥ 70 | [%] | Drive mode HV voltage | != Standby Restart processing OR != Init. OR != Standby post run ≥ 60 | [-] [-] [-] [V] | Continuous | 1.000 | [ms] | 2 DCY |
| Hybrid/EV battery system | P0AFA - Hybrid/EV Battery System Voltage Low | Inverter under voltage | Drive motor inverter voltage sensor "A" measured value | ≤ 130 | [V] | Desired drive mode Drive mode Desired drive mode signal received on FlexRay | = moment regulation OR = External rpm regulation OR = calibration OR = special brake mode != Standby Restart processing OR != Init. OR != Standby post run = valid | [-] [-] [-] [-] [-] [-] [-] [-] | Continuous | 60 | [ms] | 1 DCY |
| Ignition switch run/start position | P2535 - Ignition Switch On/Start Position "A" Circuit High | Terminal 15 voltage sensor short to battery | Terminal 15 voltage AD voltage value | > 4.90 | [V] | None | None | [-] | Continuous | 50 | [ms] | 1 DCY |
| Internal control module | U1103 - Production mode active | Production mode active | Production mode | = active | [-] | VW End of line session | = permitted OR = requested | [-] | Continuous | 1.000 | [ms] | 1 DCY |
| Development session Vehicle mileage | =permitted OR = requested ≤ 100 | [-] [km] | ||||||||||
| U0300 - Internal Control Module Software Incompatibility | Software incompatibility | Actual OBD type | != stored OBD type | [-] | Variant code | = written | [-] | Instantly | 1 DCY | |||
| U3510 - Control Module Missing Calibration | Missing calibration | Variant code | = not written OR = corrupted | [-] | Immobilizer | = downloaded | [-] | Instantly | 1 DCY | |||
| U3001 - Control Module Improper Shutdown Performance | Maximum number of resets achieved | Number of continuous resets | ≥ 5 | [-] | Monitoring not executed since previous reset | [-] | Continuous | 1 | [ms] | 1 DCY | ||
| Internal control module A/D | P060B - Internal Control Module A/D Processing Performance | AC current sensor U phase plausibility fault | U phase current error counter | > 100 | [-] | None | None | [-] | Continuous | 5 | [ms] | 1 DCY |
| AC current sensor V phase plausibility fault | V phase current error counter | > 100 | [-] | None | None | [-] | Continuous | 5 | [ms] | 1 DCY | ||
| AC current sensor W phase plausibility fault | W phase current error counter | > 100 | [-] | None | None | [-] | Continuous | 5 | [ms] | 1 DCY | ||
| Sine signal plausibility fault | Position sensor SIN signal error counter | > 100 | [-] | None | None | [-] | Continuous | 5 | [ms] | 1 DCY | ||
| Cosine signal plausibility fault | Position sensor COS signal error counter | > 100 | [-] | None | None | [-] | Continuous | 5 | [ms] | 1 DCY | ||
| Internal control module main processor | P060C - Internal Control Module Main Processor Performance | CPLD clock monitoring | Counter for CPLD Clock out of range | ≥ 4 | [-] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 5 | [ms] | 1 DCY |
| ECU error: actual torque notch filter monitoring | Actual torque notch filter monitoring | = failed | [-] | Ignition | = on | [-] | Continuous | 5 | [ms] | 1 DCY | ||
| ECU error: data flashing check | CRC error of data flash | = detected | [-] | Monitor test | = not completed | [-] | Instantly | 1 DCY | ||||
| ECU error: Drive motor inverter voltage sensor plausibility fault | | inverter side HV DC voltage - DCDC side HV DC voltage | AND HV voltage digital value | > 43.625 < 0.10 > 4.90 | [V] [V] [V] | None | None | [-] | Continuous | 35 | [ms] | 1 DCY | ||
| ECU error: torque anti-jerk function monitoring fault | Anti-jerk torque function monitoring | = failed | [-] | Ignition | = on | [-] | Continuous | 1 | [ms] | 1 DCY | ||
| ECU error: ICE rotary oscillation damper torque function monitoring fault | ICE rotary oscillation damper torque monitoring | = failed | [-] | Ignition | = on | [-] | Continuous | 1 | [ms] | 1 DCY | ||
| ECU error: Torque monitoring fault, negative side | Delivered torque | = out of range | [-] | Torque monitoring Ripoff monitoring Ignition | = passed = passed = on | [-] [-] [-] | Continuous | 120 | [ms] | 1 DCY | ||
| ECU error: Torque monitoring fault, positive side | Delivered torque for a period of time | = out of range > 2, 175 | [-] [ms] | Torque monitoring Ripoff monitoring Ignition | = passed = passed = on | [-] [-] [-] | Continuous | 5 | [ms] | 1 DCY | ||
| ECU error: Torque Monitoring HW check fault, negative side over deviation | Torque negative deviation monitoring | = failed | [-] | Torque monitoring Ripoff monitoring Ignition | = passed = passed = on | [-] [-] [-] | Continuous | 5 | [ms] | 1 DCY | ||
| ECU error: Torque Monitoring HW check fault, negative side integration over deviation | Torque negative integration deviation monitoring | = failed | [-] | Torque monitoring Ripoff monitoring Ignition | = passed = passed = on | [-] [-] [-] | Continuous | 30 | [ms] | 1 DCY | ||
| ECU error: drive motor over speed | Drive motor speed | ≤ -1, 260 ≥ 7, 460 | [rpm] | Ignition | = on | [-] | Continuous | 75 | [ms] | 1 DCY | ||
| ECU error: HV DC current during free wheel | HV DC current error at free wheel | ≥ 60 | [A] | (CPLD switching mode OR Drive motor desired mode OR Quality management error OR Security error OR Ignition OR Vehicle crash | = Free wheel OR = Active short circuit = passive mode = detected = detected = off = detected | [-] [-] [-] [-] [-] [-] | Continuous | 40 | [ms] | 1 DCY | ||
| OR Terminal 30 voltage) AND This diagnosis AND DC offset calculation | = under voltage = has not been delayed = finished | [-] [-] [-] | ||||||||||
| ECU error: Actual torque plausibility fault | | Actual torque - Delivered torque | AND Drive motor speed | > 50 > 500 | [Nm] [rpm] | CPLD switching mode | = PWM | [-] | Continuous | 130 | [ms] | 1 DCY | ||
| ECU error: Torque Monitoring HW check fault, positive side integration over deviation | Torque positive integration deviation monitoring | = failed | [-] | Torque monitoring Ripoff monitoring Ignition | = passed = passed = on | [-] [-] [-] | Continuous | 30 | [ms] | 1 DCY | ||
| ECU error: Rotor position sensor Sine / Cosine value out of range | Position sensor SIN signal OR Position sensor COS signal | ≤ 280.917 ≥ 3, 814.083 ≤ 280.917 ≥ 3, 814.083 | [-] [-] | Ignition | = on | [-] | Continuous | 35 | [ms] | 1 DCY | ||
| ECU error: Rotor position sensor sine / cosine variation fault | Sum of SIN square and COS square | ≤ 1, 054 ≥ 1, 892 | [-] | Ignition | = on | [-] | Continuous | 40 | [ms] | 1 DCY | ||
| ECU error: AC current sensor fault | Sum average of 3 phase AC currents OR Sum average of 3 phase AC currents | < 2.45 > 2.55 | [-] [-] | Ignition | = on | [-] | Continuous | 25 | [ms] | 1 DCY | ||
| ECU error: internal error check | Internal error check | =failed | [-] | Monitor test Drive mode | = not completed != Standby, Post run | [-] [-] | Continuous | 1.000 | [ms] | 1 DCY | ||
| ECU error: AC current during passive mode | | U phase current | OR | V phase current | OR | W phase current | | > 149.88 OR > 149.88 OR > 149.88 | [A] [A] [A] | (CPLD switching mode OR Drive motor desired mode OR Ignition OR Desired PWM mode) AND This diagnosis | = Free wheel OR = Active short circuit = passive mode = off = passive mode = has not been delayed | [-] [-] [-] [-] [-] | Continuous | 5 | [ms] | 1 DCY | ||
| ECU error: torque monitoring fault, drive off in wrong direction | AC current integral value | ≥ 40 | [A] | CPLD switching mode Ripoff monitoring Ignition Drive motor speed Delivered power AC current | = PWM = passed = on ≥ - 1500 AND ≤ -150 > 600 > 30 | [-] [-] [-] [rpm] [rpm] [W] [A] | Continuous | 5 | [ms] | 1 DCY | ||
| DSP state monitoring | DSP control mode and microcontroller mode | = mismatch | [-] | DCDC Current state Elapsed time after DCDC control mode has changed | = Standby OR = HvOn OR = Buck OR = Error > 80 | [-] [ms] | Continuous | 80 | [ms] | 2 DCY | ||
| DSP internal error | DSP receiving message from serial peripheral interface | = failed | [-] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 40 | [ms] | 2 DCY | ||
| DSP program run time out | DSP sending program run signal after micro controller start up | = failed | [-] | DCDC Current state | = sleep | [-] | Continuous | 1.000 | [ms] | 2 DCY | ||
| Serial peripheral interface data compatibility check Elapsed time after microcontroller startup | = not finished > 40 | [-] [ms] | ||||||||||
| Serial peripheral interface communication error | Serial peripheral interface sending or receiving monitoring | = failed | [-] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 40 | [ms] | 2 DCY | ||
| Sum of digital signal processing and serial peripheral interface | Sum value on serial peripheral interface and calculated sum value | = mismatch | [-] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 40 | [ms] | 2 DCY | ||
| Digital signal processing data | Main processor requesting data and digital signal processing sending data | = mismatch | [-] | DCDC Current state | = Standby OR = HvOn OR = Buck OR = Error | [-] | Continuous | 40 | [ms] | 2 DCY | ||
| System voltage | P0562 - System Voltage Low | Low voltage battery voltage low | Terminal 30 voltage of DMCM | ≤ 5.75 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 9.000 | [ms] | 2 DCY |
| P0563 - System Voltage High | Low voltage battery voltage high | Terminal 30 voltage of DMCM | ≥ 30 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] [-] [-] | Continuous | 9.000 | [ms] | 2 DCY | |
| P0560 - System Voltage | Terminal 30 rationality fault | | Terminal 30 voltage of DMCM - DCDC converter voltage sensor 2 | | > 4.8 | [V] | Drive mode Battery plus open monitoring status | != Standby Restart processing OR != Init. OR != Standby post run = completed | [-] [-] [-] [-] | Continuous | 320 | [ms] | 1 DCY | |
| P0563 - System Voltage High | Low voltage battery voltage circuit high | Terminal 30 voltage of DMCM AD voltage value | > 4.90 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] | Continuous | 40 | [ms] | 1 DCY | |
| P0562 - System Voltage Low | Low voltage battery voltage circuit low | Terminal 30 voltage of DMCM AD voltage value | < 0.10 | [V] | Drive mode | != Standby Restart processing OR != Init. OR != Standby post run | [-] | Continuous | 40 | [ms] | 1 DCY | |
| U1405 - Terminal 15 Implausible signal | Terminal 15 rationality check | Terminal 15 and FlexRay Terminal 15 signal | = unmatched | [-] | FlexRay signal ignition | = received | [-] | Continuous | 2.000 | [ms] | 1 DCY |
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.