2016 Audi S8 BaseFACTORY OEM SERVICE PROCEDURE

Calibrating/Adjusting with a Previous Axle Alignment

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2018 Audi S6, 2018 Audi A6 Quattro, 2018 Audi A6, 2017 Audi S6, and 2017 Audi A6 Quattro. However, it is still accessible from the selected car via links, so may be relevant.
  • Connect the battery charger. Refer to Electrical Equipment Battery, Charging.
  • Position the front wheels so they are straight. -->
  • Connect the Vehicle Diagnostic Tester to the vehicle and guide the diagnostic cable through the open window.
  • Turn off all vehicle exterior lamps.
  • Close all vehicle door.

Procedure for AllΒ 

  • Connect the Vehicle Diagnostic Tester to the vehicle and guide the diagnostic cable through the open window.
    G12616738Courtesy of AUDI OF AMERICA, LLC
  • Position the Night Vision Calibration Tool on the center of the calibration beam of the -VAS6430/1-.
  • The opening -arrows- must surround the nut and bolt -A- when the Night Vision Calibration Tool is pushed onto the calibration beam.
    G12355435Courtesy of AUDI OF AMERICA, LLC
  • Fold up the right and left bracket -A-.
  • Tighten the right and left clamping screw -1- hand-tight.
    G12355436Courtesy of AUDI OF AMERICA, LLC
  • Set up the -VAS6430/1- and the -VAS6430/6- in front of the vehicle.
  • Position the -VAS6430/6- in distance -A- to the infrared camera.
    G12355398Courtesy of AUDI OF AMERICA, LLC
NOTE: Distance -A- = 120 cm Β± 2.5 cm, measured between the -VAS6430/6- and the lens on the -R212-.
  • Attach the measuring sensor for the front wheels to the calibration beam.
    • For the following work steps, the hoist must be in the lowest position -A-.
    G12354925Courtesy of AUDI OF AMERICA, LLC
  • Install and secure the -VAS6350/3- -arrow- into the guide in the Night Vision Calibration Tool.
  • Switch on the -VAS6350/3-. A laser beam is beamed on the vehicle.
    G12355439Courtesy of AUDI OF AMERICA, LLC
  • Turn the lever on the back of the calibration board to align the laser beam so that it is in the center of the camera lens in the horizontal position.

    The specified height is now reached and the -VAS6350/3A- can be switched off.

    G12355440Courtesy of AUDI OF AMERICA, LLC
  • Level the bubble level -A- using the adjusting screw -1-.

    The bubble adjustment -A- serves to compare the ground conditions.

    G12355441Courtesy of AUDI OF AMERICA, LLC
  • Move the -VAS6430/1- sideways in direction of -arrow B- until the display on the alignment computer is within the tolerance range.
    G12355442Courtesy of AUDI OF AMERICA, LLC
  • Secure the -VAS6430/1- by tightening the bolts -2 and 3- slightly. (This prevents the -VAS6430- from rolling away).
    G12355443Courtesy of AUDI OF AMERICA, LLC
  • Turn the precision adjustment screw -1- on the calibration beam until the display on the alignment computer is located within the tolerance range.
    G12355444Courtesy of AUDI OF AMERICA, LLC
  • Level the bubble level -A- using the adjusting screw -1-.
  • Level the bubble level -B- using the adjusting screw -2-.
    G12355441Courtesy of AUDI OF AMERICA, LLC
  • Turn the -VAS6350/3- back on and check the specified height and correct if necessary. A laser beam is beamed on the vehicle.
  • Turn the lever on the back of the calibration board to align the laser beam so that it is in the center of the camera lens in the horizontal position.

    The specified height is now reached and the -VAS6350/3A- can be switched off.

    G12355440Courtesy of AUDI OF AMERICA, LLC
  • Connect the network connector -A- from the Night Vision Assist Calibration and Adjust Tool to the current network.
  • Turn on the switch -B- on the Night Vision Assist Calibration and Adjust Tool.
    G12355447Courtesy of AUDI OF AMERICA, LLC
NOTE: An internal initialization takes place after switching on the Infrared System Calibration Plate. Both LEDs -C- blink at the same time and an acoustic tone will sound if the initialization is successful and was performed without any faults. After this, the Infrared System Calibration Plate is in the ready mode. The green LED will blink slowly.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.