Left Peripheral Camera -R244- /Right Peripheral Camera -R245-, CALIBRATING
Special Tools And Workshop Equipment Required
- Calibration Tool :VAS6350
- Peripheral Camera Calibration Device :VAS6350/6
- Vehicle Diagnostic Tester
The Left Peripheral Camera -R244- /Right Peripheral Camera -R245- are installed inside the left and right exterior mirrors.
The following describes calibrating the Left Peripheral Camera -R244-. Calibrating the Right Peripheral Camera -R245- is identical.
-- Set-up requirements Calibration Tool .
-- Install and align the :VAS6350 with : VAS6350/6 . Refer to Calibration Tool .
-- Connect the Vehicle Diagnostic Tester.
Setting Up The Calibration Device
:VAS6350/1 installing:
-- Check the dimension of the holes.
-- Equip the :VAS6350/1 appropriately. Use spacer pieces.
-- To do so, secure three wheel bolt adapters in the hole circle to the :VAS6350/1 .
-- Position the paddle on the :VAS6350/1 and secure using the clamping screw.
-- Place the :VAS6350/1 on the wheel bolts on the left front wheel.
The :VAS6350/1 is positioned by the "O rings" in the adapters and held in place.
Attach the :VAS6350/1 onto the wheel so that any installed "anti-theft" wheel mounting bolts are not connected to the :VAS6350/1 .
-- Position the equipped :VAS6350 with the :VAS6350/6 -4- near the vehicle.
-- Adjust the paddle -2- with a clamping screw so that it moves freely and easily just over the :VAS6350 -4- calibration platform.
Installing the :VAS6350/3 :
-- Install the :VAS6350/6-5 -2- all the way using the 3/8" fine toothed ratchet on the left rear wheel and install the :VAS6350/6-6 together with the :VAS6350/3 -1-.
-- Slide the :VAS6350/6-6 so that the outer edge of the :VAS6350/6-5 is flush with the outer edge of the laser housing -arrow-. Tighten the clamping lever.
:VAS6350 with :VAS6350/6 Orientation
-- Switch on the :VAS6350/3 -3- and adjust the laser beam forward toward the :VAS6350/1 -2- such that a line appears on the :VAS6350 -4- calibration field.
-- Adjust the :VAS6350 -4- calibration field such that the outer edge of the black line on the :VAS6350 -4- calibration field is exactly on the laser beam.
-- Adjust the :VAS6350 -4- calibration field relative to the outer edge of the black line -1- so that it lines up exactly with the free-hanging paddle on the :VAS6350/1 -2-.
-- Bring the : VAS6350 with :VAS6350/6 into a horizontal position.
-- To do so, twist plastic feet under the calibration field of the :VAS6350 so that air bubble in level is located exactly in the center of the indicator -arrow-
Make sure light does not reflect off the :VAS6350/6 .
Reflections affect the camera and may make it impossible to perform the calibration.
Dimension Measurement -h-
-- Measure the height of the :VAS6350 -2- calibration field, dimension -h-, from the surface of the :VAS6350 -2- calibration field (not the aluminum frame) down to the floor. Measure the hole in the :VAS6350 -2- calibration field.
Make sure the :VAS6350/2 -1- is adjusted correctly (attach with front edge).
The display shows how to stop the :VAS6350/2 . Press the corresponding button.
- Attach with front edge
- Attach with rear edge
Dimension -h- and the distance dimension must now be entered into the Vehicle Diagnostic Tester in "millimeters".
Performing Calibration
Vehicle Diagnostic Tester is attached.
-- Select the Diagnostic mode and start the diagnostics.
-- Select the tab Test Plan .
-- Select Select Individual Tests and choose the following sequence.
- Body
- Electrical Equipment
- 01 - OBD-capable systems
- 6C - peripheral camera control module | J928
- 6C - peripheral camera control module, functions
- 6C - Calibration, (Repair Group 91)
The Vehicle Diagnostic Tester continues with the calibrating procedure from here on.
Make sure light does not reflect off the :VAS6350/6 .
Reflections affect the camera and may make it impossible to perform the calibration.
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.