2001 Audi S4 Quattro, AutomaticFACTORY OEM SERVICE PROCEDURE

Fuel System Residual Pressure

  1. Connect Pressure Gauge (VAG 1318) between fuel supply and fuel return lines in engine compartment. See Figure . Start engine and let it idle. Turn engine off.
  2. After 10 minutes observe fuel pressure gauge. If residual fuel pressure is as specified, residual fuel pressure is okay. See appropriate FUEL PRESSURE SPECIFICATIONS table, go to FUEL SYSTEM PRESSUREΒ  . If residual fuel pressure is less than minimum, check fuel lines for leaks and repair as necessary. Check fuel pressure regulator for leaks. Check fuel injectors for leaks. See FUEL INJECTOR TESTΒ  .
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.