1996 Audi A4 Base, AutomaticFACTORY OEM SERVICE PROCEDURE

Fuel Pump Check Valve Test

  1. Connect Pressure Gauge (VAG 1318) between fuel supply and fuel return lines in engine compartment. Ensure pressure gauge test valve is in OPEN position.
  2. Operate remote control switch for approximately 30 seconds. Move pressure gauge test valve to CLOSED position. Briefly operate remote control switch until maximum of 80 psi (5.5 bar) is indicated. Observe pressure drop on fuel pressure gauge.
  3. After 10 minutes, maximum allowable pressure drop is 7 psi (.5 bar). If pressure drop is more than allowable maximum, ensure no fuel leaks are present in fuel lines. If no fuel leaks are present in fuel lines, fuel pump check valve is defective. Replace fuel pump.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.

Rather have a pro handle this?

A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.

Comes to youSame-day available12-month warranty
Get a Free Quote

No obligation. See pricing before you book.