1994 Audi S4FACTORY OEM SERVICE PROCEDURE

Checking Electrically

  1. Disconnect harness connector at wastegate by-pass regulator valve. See Fig 1.
  2. Connect DVOM multimeter switched to resistance range to wastegate by-pass regulator valve, using adapters from (VW 1594) connector test kit. See Fig 2.
  3. Measure resistance, must be 25-35 ohms. If NO: Replace wastegate by-pass regulator valve.
Fig 1: Locating Wastegate By-Pass Regulator Valve
G00177362Courtesy of AUDI OF AMERICA, INC.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.