1994 Audi S4FACTORY OEM SERVICE PROCEDURE

Fuel Injector Volume

NOTE: Always use NEW fuel injector seals, moistened with clean engine oil. Take care not to damage the seals during installation.

Remove fuel injectors from intake manifold. See FUEL INJECTOR LEAKAGEΒ .

  1. Hold fuel injector to be tested in measuring glass from fuel analyzer (VAG 1602). Operate remote control (VW 1348/3A) for 30 seconds.
  2. Output must be 150-170 ml (5.1-5.7 ozs.).
  3. If measured volume from one or more fuel injectors is above or below specified volume: Replace faulty fuel injector.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.