1994 Audi 90 CS QuattroFACTORY OEM SERVICE PROCEDURE

Intake Manifold Change-Over (IMCO) Valve

  1. Increase engine speed to more than 4100 RPM. If IMCO valve vacuum motor is actuated, system is okay. If IMCO valve vacuum motor is not actuated, disconnect electrical connector from IMCO valve control solenoid. See ELECTRICAL COMPONENT LOCATIONSΒ  table at beginning of article.
  2. Measure resistance across terminals of IMCO valve control solenoid. If resistance is not 25-35 ohms, replace IMCO valve control solenoid. If resistance is 25-35 ohms, apply battery voltage across terminals of IMCO valve control solenoid. Replace IMCO valve control solenoid if it does not operate. If IMCO valve control solenoid operates, check ECM and wiring.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.