1990 Audi 90 Base, 2.3 C, AutomaticFACTORY OEM SERVICE PROCEDURE

Deceleration Fuel Shutoff

  1. Ensure engine is at normal operating temperature and no fault codes are stored in ECU memory. Using a digital voltmeter and Adapter (VW 1315A/1), check voltage at differential pressure regulator.
  2. Connect voltmeter to differential pressure regulator using adapter. See Figure . Turn ignition on. Control voltage must be positive (+). If voltage is negative (-), reverse test leads.
  3. Start engine. Raise engine speed to 3000 RPM and release throttle. Control voltage should switch to negative (-) momentarily. If system fails test, perform electrical tests. See Figure and the CIS-MOTRONIC VOLTAGE & RESISTANCE TESTS  table. If system electrical tests are okay, replace ECU and clear fault codes.
CIS-MOTRONIC VOLTAGE & RESISTANCE TESTS

Test Step Terminals Test Conditions Test Values
No. 1 14 & 35 Ignition ON About Battery Voltage
No. 2 17 & 35 Ignition ON About Battery Voltage
No. 3 32 & 35 Ignition & A/C ON About Battery Voltage
No. 4 33 & 35 Ignition & A/C ON Battery Volts Minus 1
No. 5 19 & 35 Ignition ON About Battery Voltage
No. 6 (1) 13 & 35 Insert Fuel Fault Indicator
" " Relay Fuse Must Light
" " Ignition ON Fault Indicator Must Light
No. 7 4 & 5 Ignition OFF 15-25 Ohms
No. 8 3 & 35 Ignition OFF 2500 Ohms @ 68°F (20°C)
" " " 200 Ohms @ 212°F (100°C)
No. 9 31 & 35 Throttle Closed Open (No Continuity)
" " Throttle Wide Open Continuity
No. 10 28 & 35 Throttle Closed & Open Continuity
No. 11 (2) 18 & 35 " Continuity
No. 12 13 & 35 Insert Fuel Relay Fuse Continuity
" 13 & 35 Ground Test Connector Continuity
No. 13 14 & 16 Cold Start Valve Test About 10 Ohms
No. 14 14 & 15 Charcoal Canister Valve Test 30-60 Ohms
No. 15 " Unplug Hall Effect Sensor Connector "
" 30 & 35 Terminals 1 & 2 To Sensor Continuity
" 30 & 21 Terminals 2 & 3 To Sensor Continuity
No. 16 11 & 35 Remove Terminal @ Power Output Stage "
" " Of Coil. Ground Center Contact Continuity
No. 17 " Disconnect Knock Sensor Connector Open
" 6 & 8 Connect Terminals 1 & 2 Continuity
" " Connect Terminals 1 & 3 Continuity
No. 18 7 & 35 Disconnect O2 Connector & Gnd Continuity
No. 19 23 & 26 Sensor Plate @ Rest About 5000 Ohms
No. 20 26 & 35 Sensor Plate @ Rest About 4000 Ohms
No. 21 34 & 35 Man. Trans. Continuity
" " Auto. Trans. In "P" Or "N" Open
No. 22 12 & 35 Remove Fuel Pump Relay & Ground "
" " Pin 47 Of Fuse Panel Relay Continuity
(1) California only.
(2) Non-California only.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.