1988 Audi 5000 CS, StandardFACTORY OEM SERVICE PROCEDURE

All Models

  1. Item Being Tested - Anti-Lock Power Supply Relay Place ABS tester in program switch position No. 5. Turn ignition off. Disconnect plug for anti-lock brake tester from ABS control unit.
  2. Remove anti-lock power supply relay from auxiliary relay panel. Use ABS tester adapter to connect anti-lock power supply relay from vehicle to back of ABS tester. See Figure .
  3. Install a new Anti-Lock Power Supply Relay (443 927 826) in auxiliary relay panel. Turn ignition on. When button No. 5 lights up, press button.
  4. Lamps No. 1 and 3 (Green) must come on. If lamps come on, TEST 5 is completed. If lamp No. 4 (Red) comes on, repeat steps 1) through 3). If lamp No. 4 comes on again, replace anti-lock power supply relay.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.