1987 Audi 5000 CS, AutomaticFACTORY OEM SERVICE PROCEDURE

Sensor Plate Clearance Adjustment

  1. Remove fuel distributor from airflow sensor housing. Turn distributor upside-down to access stop screw for control piston. This will adjust free play travel range of sensor plate lever.
  2. Turning screw clockwise will increase clearance by keeping control piston higher in fuel distributor during operation. Turning screw counterclockwise will decrease clearance by allowing control piston to extend further out of fuel distributor during operation.
  3. Adjusting stop screw 1/4 turn (90 degrees) will make .05" (1.3 mm) difference at sensor plate. Idle speed and CO (current reading) must be checked.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.