Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
1987 Audi 5000 CS, AutomaticFACTORY OEM SERVICE PROCEDURE
Hall Sender
- Disconnect coil wire from distributor cap. Using a jumper wire, ground the coil wire. Disconnect hall sender-to-ICU harness connector.
- Connect multimeter between terminals No. 1 and No. 3 of connector "D". See Fig 1 . Turn ignition to "ON" position. Reading should be at least 9 volts. If not to specification, repair break in wiring. Turn ignition off.
- If step 2) tests satisfactory, push back rubber boot on hall sender connector. Connect multimeter between terminals No. 1 and No. 2. Reconnect hall sender-to-ICU harness connector.
- Turn ignition to "ON" position. Remove ignition distributor cap, rotor and dust cap. DO NOT allow spring clips to fall inward toward trigger wheel.
- Using Wrench (2079 ), turn crankshaft until trigger wheel is clear of hall sender. Multimeter should read a minimum of 4 volts. Turn crankshaft until trigger window is aligned with hall sender.
- Reading should be between .0-.5 volts. Turn ignition off. If reading was not to specification, replace hall sender. If reading was correct, check wiring between hall sender connector and ICU.
- Remove ICU cover from left side kick panel. Disconnect harness connector from ICU and Connector "D" from distributor. Check for continuity between distributor connector pins and appropriate 25-pin ICU connector pins. For correct pin-to-pin reference, see Fig 1 and Fig 2 Also see WIRING DIAGRAMSΒ .
- If hall sender and wiring between connector "D" and the ICU connector tested satisfactory, replace ICU.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.