1983 Audi 5000 BaseFACTORY OEM SERVICE PROCEDURE

Injection Pump Timing

NOTE: Before starting timing procedure, check valve timing and drive belt tension.
  1. Set crankshaft to TDC on No. 1 cylinder and align marks on flywheel and clutch housing. Check marks on injection pump sprocket and mounting plate.
  2. If timing adjustment is necessary, remove plug from injection pump cover and install adapter and dial indicator in place of plug. Loosen cold start device cable by loosening screw No. 1 and turning clamp 90Β°. See Fig 1 .
    Fig 1: Loosening Cold Start Device Screw No. 1
    G34581
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.