2021 Acura TLX BaseFACTORY OEM SERVICE PROCEDURE

DTC Advanced Diagnostics: P04F1 (2.0L Engine)

DTC P04F1:  Evaporative Emission (EVAP) System Low Purge Flow Detected

General Description 

GHH479754Courtesy of HONDA, U.S.A., INC.
GHH479755Courtesy of HONDA, U.S.A., INC.
Negative side purge flow Boost side purge flow Purge back-flow (P2450) Condition
Flowing Flowing OK Purge line normal, EVAP canister purge valve normal
Flowing Flowing NG (P2450) Non-return valve A abnormal
Not flowing Flowing - Negative side purge line abnormal
Flowing Not flowing - Boost side purge line abnormal
Not flowing Not flowing - Purge line abnormal, EVAP canister purge valve open

The fuel vapor in the fuel tank is temporarily stored in the evaporative emission (EVAP) canister and drawn into the engine through the EVAP canister purge valve. The powertrain control module (PCM) controls the amount of vapor introduced into the engine by varying the duty cycle of the EVAP canister purge valve according to the condition of the engine.

The PCM checks the purge flow conditions on both negative and boost pressure sides. If either side of the purge flow is detected as abnormal, it is determined that there is a clog or disconnection on the abnormal side of the purge line. If both sides of the purge flow are detected as abnormal, it is determined that the purge lines are abnormal or the EVAP canister purge valve is stuck opened.

Purge flow check of negative pressure side:

<STEP 1>

The EVAP canister purge valve opens normally (EVAP canister purge valve OPEN OK) and detects that the purge flow is normal when the pulse of the EVAP canister purge valve duty cycle is transmitted to the fuel tank pressure (FTP) sensor during purge flow (pulse method).

OK determination: Pulse exists (P0441 OK)

  • P04F1 Purge flow OK
  • P04DF EVAP canister purge valve stuck Open OK

NG determination: No pulse (P0441 NG)

  • Either purge flow P04F1 abnormality or P04DF EVAP canister purge valve OPEN failure
  • In this case, classify the failed part according to <STEP 2>

<STEP 2>

If there is no pulse, it is determined as either no purge flow or the EVAP canister purge valve is stuck OPEN:

When the FTP sensor fluctuates from negative pressure to atmospheric pressure after the vehicle condition is turned to the OFF (LOCK) mode: P04DF EVAP canister purge valve stuck OPEN

When there is no fluctuation of the FTP sensor: P04F1 purge flow NG

Monitor Execution, Sequence, Duration, DTC Type 

Execution Once per driving cycle
Sequence P0441 is judged as NG
Duration -
DTC Type Two drive cycles, MIL on

Enable Conditions 

Condition Minimum Maximum
Low load duration time 10 seconds -
Wait for stability after the vehicle condition is turned to the OFF (LOCK) mode 10 seconds -
Engine coolant temperature [ECT Sensor 1] before EVAP purge control starts 131 deg.F (55 deg.C) -

[ ]: HDS Parameter

Malfunction Threshold 

The output from the FTP sensor [FTP Sensor] is less than 0.27 kPa (2.00 mmHg, 0.079 inHg).

Possible Cause 

NOTE: The causes shown may not be a complete list of all potential problems, and it is possible that there may be other causes.
  • EVAP canister purge valve closed stuck
  • FTP sensor stuck
  • EVAP system line clogged
  • EVAP system line misinstalled

Confirmation Procedure 

Operating Condition 

  • Start the engine. Hold the engine speed [Engine Speed] at 3, 000 rpm without load (in P or N) until the radiator fan comes on.
  • Let the engine idle for at least 55 seconds.
  • Drive the vehicle at high load for total of at least 9.5 seconds.
  • Turn the vehicle to the OFF (LOCK) mode and leave the vehicle for at least 10 seconds.
  • Drive the vehicle in this manner only if the traffic regulations and ambient conditions allow.

With the HDS 

Select the EVAP TEST in the Function Test, then select the FUNCTION TEST with the HDS.

Diagnosis Details 

Conditions for setting the DTC 

When a malfunction is detected during the first drive cycle, a Pending DTC is stored in the PCM memory. If the malfunction returns in the next (second) drive cycle, the MIL comes on and a Confirmed DTC, the freeze data, and the on-board snapshot are stored.

Conditions for clearing the DTC 

The MIL is cleared if the malfunction does not return in three consecutive trips in which the diagnostic runs. The MIL, the Pending DTC, the Confirmed DTC, the freeze data, and the on-board snapshot can be cleared with the scan tool clear command.

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.