2012 Acura ZDX V6-3.7LFACTORY OEM SERVICE PROCEDURE

Ignition Switch Test




Ignition Switch Test

NOTE: SRS components are located in this area. Review the SRS component locations Locations, and precautions and procedures Service and Repair before doing repairs or servicing.

1. Do the battery terminal disconnection procedure Procedures.

2. Remove the steering column covers Service and Repair.

3. Remove the two screws, harness clip, and bracket (A).

Factory service manual diagram





4. Disconnect the 5P connector (B) from the ignition switch (C).

5. Check for continuity between the terminals in each switch position according to the table.

Factory service manual diagram




6. If the continuity is not as specified, replace the ignition switch Service and Repair.

7. Do the battery terminal reconnection procedure Procedures.