2012 Acura TL BaseFACTORY OEM SERVICE PROCEDURE

DTC P0496: EVAP System High Purge Flow Detected

NOTE: Before you troubleshoot, record all freeze data and any on-board snapshot, and review the general troubleshooting information (see GENERAL TROUBLESHOOTING INFORMATION ).
  1. Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode.
  2. Clear the DTC with the HDS.
  3. Do the EVAP FUNCTION TEST in the INSPECTION MENU with the HDS.

    Is the result OK? 

    YES  - Intermittent failure, the system is OK at this time. Check for poor connections or loose terminals at the FTP sensor, the EVAP canister purge valve, the EVAP canister vent shut valve, and the ECM/PCM.

    NO  - Go to step 4.

    NOTE: If the test could not be completed because of another DTC, do the troubleshooting for that DTC, then go to step 4.
  4. Turn the ignition switch to LOCK (0), or press the engine start/stop button to select the OFF mode.
  5. Replace the EVAP canister purge valve (see EVAP CANISTER PURGE VALVE REPLACEMENT  ).
  6. Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode.
  7. Reset the ECM/PCM with the HDS.
  8. Do the ECM/PCM idle learn procedure (see ECM/PCM IDLE LEARN PROCEDURE ).
  9. Do the EVAP FUNCTION TEST in the INSPECTION MENU with the HDS.

    Is the result OK? 

    YES  - Troubleshooting is complete.

    NO  - Check for poor connections or loose terminals at the FTP sensor, the EVAP canister purge valve, the EVAP canister vent shut valve, and the ECM/PCM, then go to step  1.

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.