2012 Acura RLFACTORY OEM SERVICE PROCEDURE

Shift Lock Solenoid Test

  1. Connect the HDS to the DLC (A).
    Fig 1: Identifying Data Link Connector
    G07362526Courtesy of AMERICAN HONDA MOTOR CO., INC.
  2. Turn the ignition switch to ON (II). Make sure the HDS communicates with the PCM. If it does not, go to the DLC circuit troubleshooting (see DLC CIRCUIT TROUBLESHOOTING ).
  3. Select Shift Lock Solenoid Test in the Miscellaneous Test Menu, and check that the shift lock solenoid operates with the HDS.
  4. Check that the shift lever can be moved out of P when the Shift Lock Solenoid is ON. Move the shift lever back to P, and check that it locks with Shift Lock Solenoid is OFF.
  5. Check that the shift lock releases when the shift lock release is pushed, and check that it locks when the shift lock release is released.
  6. If the shift lock solenoid does not works properly, go to the SHIFT LOCK SYSTEM CIRCUIT TROUBLESHOOTINGΒ  .