2012 Acura RLFACTORY OEM SERVICE PROCEDURE

EVAP Canister Vent Shut Valve Replacement

  1. Remove the trunk front trim panel (see TRIM REMOVAL/INSTALLATION - TRUNK AREA ).
  2. Remove the access panel (A) from the floor.
    Fig 1: Removing Access Panel From Floor
    G07362134Courtesy of AMERICAN HONDA MOTOR CO., INC.
  3. Disconnect the EVAP canister vent shut valve connector (A), FTP sensor connector (B), and the hose (C).
    Fig 2: Disconnecting EVAP Canister Vent Shut Valve Connector, FTP Sensor Connector And Hose
    G07362135Courtesy of AMERICAN HONDA MOTOR CO., INC.
  4. Pry the lock tabs (D) outward, and remove the EVAP canister vent shut valve (E).
    NOTE: Be careful not to damage the lock tabs.
  5. Install the parts in the reverse order of removal with a new O-ring (F).
    NOTE: Do not coat the new O-ring with oil or other lubricants.